3
16 sensors
can be installed for one engine at the maximum.
16 sensors
can be installed in total at the maximum for two engines,
8 sensors
each for an engine.
*
Wire the sensors in daisy chain system (connection-in-a-row system) for each engine.
Limit the total length of the telecommunication cable from the sensor of an end to a controller is less than
150 m
(for use of Daihatsu option cables). In case of the total wire length exceed 150 m, please ask the wiring
method to Daihatsu.
The wiring between sensors and controller shall be used Daihatsu option cables (the cable with connectors).
(Note: When installing a junction box between a controller and sensors, a general cable for ships can be used
between the controller and the junction box.)
Mount the sensor directly on the engine frame.
Use the specified rubber cushions to isolate the controller from vibration if it is directly mounted on the
engine body.
Before using the mounting method described above, please contact us.
For ship use, it may be limited by the shipping classification society with one oil mist detector system 1
formula per engine. Please follow the rule of each shipping classification society.
For sensor wiring method, The loop wiring also applicable other than daisy chain method
(
Please refer to 16.4 Attention of using LOOP wiring for sensor cable routing
)
Original content from www.daihatsu.cc
Issued to HORIZON TANKERS LIMITED S.A.