Connecting Basics
40
Make sure the front-end device has soundly earthed
Improper grounding might result in chip damage.
4.3.1 Introducing Alarm Port
The alarm input ports are dependent on the model you purchased.
Figure 4-3
Icon
Description
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
,
12
,
13
,
14
,
15
,
16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
NO1 C1, NO2 C2,
NO3 C3, NO4 C4
There are four groups of normally open activation output (on/off button).
NO5 C5 NC5,
There is one group of normally open activation output (on/off button).
CTRL 12V
Control power output of the alarm output channel 6. Electric current:
500mA.
When there is an alarm output, close the power output.
When the alarm is cancelled, open the power output.
+12V
Rated power supply.
Electric current: 500mA.
Ground cable.
485 A/B
485 communication port. They are used to control devices such as
decoder.
120Ω should be parallel connected between A, B lines if there
are too many PTZ decoders.
T+,T-,R+,R-
Four-wire full-duplex RS-485 port.
T+ T-: output wire.
R+ R-: input wire.
Table 4-1
4.3.2 Alarm Input
Refer to the following figure for more information.
Grounding alarm inputs which includes NO (Normally Open) and NC (Normally Closed)
type.
Parallel connect COM end and GND end of the alarm detector (Provide external power to
the alarm detector).
Parallel connect the Ground of the DVR and the ground of the alarm detector.
Содержание XVR Cooper Series
Страница 1: ...DIGITAL VIDEO RECORDER User s Manual V1 3 0...
Страница 53: ...Connecting Basics 37 Figure 4 2...
Страница 198: ...Local Configurations 182 Figure 5 147 Figure 5 148...
Страница 220: ...Local Configurations 204 Figure 5 170 Figure 5 171 Double click the video or click Step 7...
Страница 287: ...Local Configurations 271 Figure 5 242 Figure 5 243...
Страница 337: ...Glossary 321 Abbreviations Full term VGA Video Graphics Array WAN Wide Area Network...
Страница 355: ...Earthing 339...