DESCRIPTION

 

 

AUTOMATIC REGULATOR FOR PUMPS

 

Smart Press

 is an automatic electronic device, designed to 

regulate pump operation, without using autoclave tanks. 

Smart Press

 performs the following operations:  

1)

 

Controls pump operation, automatically and without 

interruption, with constant pressure and delivery during 
supply from one or more distribution points. 
The pump starts when the pressure of the system is less than 
the fixed pressure (std 1.5 bar). Il stops when 

Smart Press

 

no longer detects an appreciable outlet flow (see point 2). 
2)

 

Keeps the pump operating for a brief period 

(approximately 5 seconds) after supply has stopped at the tap 
closing. 
3)

 

If there is no water at the suction point, it blocks the 

pump,without using level probes or float switches. Or it 
releases automatically when a pressure above the one 
required to start the motor-driven pump is injected in the 
delivery line. 

 

One version of system  is identified as Smart Press WG 
(where WG is for Water Guardian).   
In case of block due to lack of water, this system effects 
some tries of automatic random, as equal as pressing  the 
pushbutton of manual reset, every 30 Min. 

 

4)

 

It is supplied with a flow sensor, manufactured with a 

geometry which reduces the loading losses even with very 
high flows. 
5)

 

Lights indicate the various operation phases:  

green LED on

:

 

present power supply

 

yellow LED on

pump working 

red LED on

:

  blocked due to lack of water at supply point.  

 

OPERATING CONDITIONS

 

 Smart 

Press 

WG 1,5HP   

230V 

Smart Press 

WG 3HP  

 230V 

Smart Press 

WG 1,5HP  

115V 

Maximum 
working pressure 

 

15 BAR 

Standard starting 
calibration 

 

1,5 BAR 

Maximum liquid 
temperature 

 

45° C 

Power supply 

1F ~ 220-240V 

 50-60 Hz  

(+/- 6%) 

1F ~ 100-127V 

50-60 Hz 

(+/- 6%)

 

Maximum 
current 
strength 

 

10A cos

φ

 

 0,7

 

 

20A cos

φ

 

 0,7

 

Protection 
degree 

 

IP 55 

Hydraulic 
connections 

IN 1” M 

OUT 1” ¼ F 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION 

Warning!

 

During installation, as well as during any maintenance 
operations, the electrical power supply must be disconnected 
by removing the cord or using the switch. The electrical 
connection must be made by a trained individual following 
the safety regulations in force. 

 

a)

 

Normally the 

Smart Press

 is mounted directly on the 

delivery point of a surface pump: the device is connected with 
a l" male, however it can be mounted at any point on the 
delivery piping (even on a submerged pump) in a vertical or 
horizontal position. Avoid applying check valves 

to the 

downstream

on recommend the application to the 

upstream. 

 

b)

 

The 

Smart Press

 delivery should be connected to the 

water supply (1 ¼" female) 

on recommend to

 

use

 a flexible 

hose to prevent damage from tightening and /or vibration. 

 

c)

 

The standard model of 

Smart Press

 

works correctly 

if 

the highest point of use 

doesn't overcome

 15 meters highs. 

Change this value using the setting screw (dowel) on the front 
side of the 

Smart Press

. Turn the screw clockwise to 

increase the ignition value. Turn counterclockwise to reduce 
the ignition value.  
d)

 

Make sure that the pump primes perfectly by filling the 

body of the pump and suction hose with water. If the pump is 
going to be used with supply from a low level (well) always 
install a foot valve.  
e)

 

Perform electric connection observing the serigraphy on 

the electronic card located in front of the clamps.

 

 
TROUBLESHOOTING

 

 

 

THE PUMP JAMS:

 

(red LED on)

 reset the priming and 

eliminate the cause of the failure to prime (suction leak, 
malfunctioning foot valve, tank without water, etc.). Then 
press the manual reset button being careful not to run the 
pump with no water to prevent damaging the seal and 
hydraulic part.  

 

THE PUMP GOES ON AND OFF CONTINUOUSLY:  

find the leak in the delivery system and eliminate it.  

 

THE EQUIPMENT IS COMPLETELY OFF (NO LlGHT 
ON) AND WILL NOT START AGAIN:

 

Check the power supply

. If the board has been removed for 

replacement or for easier wiring, check if the flux sensor 
located in the rear part of the board, is properly located in its 
housing in the main body, while carefully avoiding to crush 
the feet which cause the board to stop completely. 

 

 

Содержание SMART PRESS WG 1,5HP

Страница 1: ...TRUCTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONSANWEISUNG UND WARTUNG INSTRUCCIONES PARA LA INSTALACI N Y EL MANTENIMIENTO INSTRU ES PARA A INSTALA O E A MANUTEN O INSTRUCTIES VOOR INSTALLATIE...

Страница 2: ...1 185 mm 180 mm 115 mm...

Страница 3: ...ne l energia elettrica deve essere disinserita stac cando la spina od agendo su apposito interruttore L allacciamento elettrico va eseguito da personale specializza to nel rispetto delle normative di...

Страница 4: ...aintenance l nergie lectrique doit tre coup e en d branchant la prise ou en teignant l interrupteur Le branchement lectrique doit tre effectu par un personnel sp cialis dans le respect des normes de s...

Страница 5: ...ations the electrical power supply must be disconnected by removing the cord or using the switch The electrical connection must be made by a trained individual following the safety regulations in forc...

Страница 6: ...er Installation wie auch w hrend jeder Wartung muss die elektrische Stromzufuhr unterbrochen werden Netzstecker ziehen Installation und Betrieb m ssen den Sicherheitsvorschriften des jeweiligen Landes...

Страница 7: ...1 M INSTALACI N Atenci n Durante la instalaci n como as tambi n durante cada operaci n de mantenimiento corte la energ a el ctrica desconectando el enchufe o apagando el interruptor La conexi n el ctr...

Страница 8: ...instala o como tamb m durante cada opera o de manuten o a energia el ctrica deve ser desligada retirando a tomada ou desligando o interruptor A liga o el ctrica deve ser feita por pessoal especializad...

Страница 9: ...uardian 30 4 5 Smart Press WG 1 5HP 230V Smart Press WG 3HP 230V Smart Press WG 1 5HP 115V 15 BAR 1 5 BAR 45 C 1F 220 240V 50 60 Hz 6 1F 100 127V 50 60 Hz 6 10A cos 0 7 20A cos 0 7 IP 55 IN 1 M OUT 1...

Страница 10: ...worden uitgeschakeld door de stekker uit het stopcontact te trekken of de hiervoor bestemde schakelaar om te zetten De elektrische aansluiting dient te worden verzorgd door gespecialiseerd personeel...

Страница 11: ...mart Press WG WG 30 reset 4 5 Smart Press WG 1 5HP 230V Smart Press WG 3HP 230V Smart Press WG 1 5HP 115V 15 BAR 1 5 BAR 45o C 1F 220 240V 50 60 Hz 6 1F 100 127V 50 60 Hz 6 10A cos 0 7 20 cos 0 7 55 1...

Страница 12: ...art Press WG WG Water Guardian 30 4 5 LED LED LED Smart Press WG 1 5HP 230V Smart Press WG 3HP 230V Smart Press WG 1 5HP 115V 15 1 5 45 1F 220 240V 50 60 Hz 6 1F 100 127V 50 60 Hz 6 10A cos 0 7 20A co...

Страница 13: ...WG WG 30 4 5 Smart Press WG 1 5HP 230v Smart Press WG 3HP 230v Smart Press WG 1 5HP 115v 1 5 bar 1 5 bar 45 c 1F 220 240v 50 60Hz 6 1F 100 127v 50 60Hz 6 10Acos 0 7 20Acos 0 7 1 4 1 1 a SMART PRESS b...

Страница 14: ...lektromos csatlakoz dugasz kih z s val vagy ha ki p tett a f kapcsol lekapcsol s val Az elektromos bek t st speci lisan k pszet szakembernek kell v geznie az rv nyes biztons gi el r sok betart s val d...

Страница 15: ...WG WG 30 4 5 Smart Press WG 1 5HP 230V Smart Press WG 3HP 230V Smart Press WG 1 5HP 115V 15 1 5 45 C 1F 220 240V 50 60 Hz Toll 6 1F 100 127V 50 60 Hz Toll 6 10A cos 0 7 20A cos 0 7 IP 55 IN 1 M OUT 1...

Страница 16: ...w a ciwym prze cznikiem Pod czenia elektryczne powinien wykona wykwalifikowany personel zgodnie z obowi zuj cymi przepisami bezpiecze stwa g Z regu y Smart Press jest instalowany bezpo rednio na wej c...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...x 32 2 4669218 DAB PUMPS IBERICA S L Avenida de Castilla nr 1 Local 14 28830 San Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 DAB PUMPS INC 3226 Benchmar...

Отзывы: