![D-Link xStack DGS-3600 Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/d-link/xstack-dgs-3600-series/xstack-dgs-3600-series_cli-manual_4127464081.webp)
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
78
create syslog host
7 Debug: debug-level messages
informational
−
Specifies that informational messages will be sent to the
remote host. This corresponds to number 6 from the list above.
warning
−
Specifies that warning messages will be sent to the remote
host. This corresponds to number 4 from the list above.
all
−
Specifies that all of the currently supported syslog messages that
are generated by the Switch will be sent to the remote host.
facility
−
Some of the operating system daemons and processes have
been assigned Facility values. Processes and daemons that have not
been explicitly assigned a Facility may use any of the "local use" facilities
or they may use the "user-level" Facility. Those Facilities that have been
designated are shown in the following:
Bold
font indicates the facility
values that the Switch currently supports.
Numerical Facility
Code
0 kernel messages
1 user-level messages
2 mail system
3 system daemons
4 security/authorization messages
5 messages generated internally by syslog
6 line printer subsystem
7 network news subsystem
8 UUCP subsystem
9 clock daemon
10 security/authorization messages
11 FTP daemon
12 NTP subsystem
13 log audit
14 log alert
15 clock daemon
16 local use 0 (local0)
17 local use 1 (local1)
18 local use 2 (local2)
19 local use 3 (local3)
20 local use 4 (local4)
21 local use 5 (local5)
22 local use 6 (local6)
23 local use 7 (local7)
local0
−
Specifies that local use 0 messages will be sent to the remote
host. This corresponds to number 16 from the list above.
local1
−
Specifies that local use 1 messages will be sent to the remote
host. This corresponds to number 17 from the list above.
local2
−
Specifies that local use 2 messages will be sent to the remote
host. This corresponds to number 18 from the list above.
local3
−
Specifies that local use 3 messages will be sent to the remote
host. This corresponds to number 19 from the list above.
local4
−
Specifies that local use 4 messages will be sent to the remote
host. This corresponds to number 20 from the list above.
local5
−
Specifies that local use 5 messages will be sent to the remote
host. This corresponds to number 21 from the list above.
local6
−
Specifies that local use 6 messages will be sent to the remote
host. This corresponds to number 22 from the list above.
local7
−
Specifies that local use 7 messages will be sent to the remote
host. This corresponds to number 23 from the list above.
udp_port <udp_port_number>
−
Specifies the UDP port number that the