Example
To map a VLAN ID to an MSTP instance:
DGS-3420-28SC:admin#config stp instance_id 2 add_vlan 1
Command: config stp instance_id 2 add_vlan 1
Success.
DGS-3420-28SC:admin#
To remove a VLAN ID from an MSTP instance:
DGS-3420-28SC:admin#config stp instance_id 2 remove_vlan 2
Command: config stp instance_id 2 remove_vlan 2
Success.
DGS-3420-28SC:admin#
16-8
config stp mst_config_id
Description
This command is used to configure a configuration name or revision level in the MST configuration
identification. The default configuration name is the MAC address of the bridge.
Format
config stp mst_config_id {revision_level <int 0-65535> | name <string>} (1)
Parameters
revision_level
- Specify the revision level.
<int 0-65535>
- Specify the revision level.
name
- Specify the name given for a specified MST region.
<string>
- Specify the name given for a specified MST region.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To change the name and revision level of the MST configuration identification:
DGS-3420-28SC:admin#config stp mst_config_id revision_level 1 name R&D_BlockG
Commands: config stp mst_config_id revision_level 1 name R&D_BlockG
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...