xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
857
<ipv6addr>
- Specifies the IPv6 used.
collectorport
- (Optional) Specify the destination port for sending sflow datagrams.
<udp_port_number 1-65535>
- Specify the destination port for sending sflow datagrams. The
number is between 1 and 65535.
maxdatagramsize
- (Optional) Specify the maximum number of data bytes that can be packed in a
single sample datagram.
<value 300-1400>
- Specify the maximum number of data bytes that can be packed in a single
sample datagram. The values is between 300 and 1400.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the sFlow analyzer server information:
DGS-3420-28SC:admin#config sflow analyzer_server 1 collectoraddress 10.90.90.9
Command: config sflow analyzer_server 1 collectoraddress 10.90.90.9
Success.
DGS-3420-28SC:admin#
12-10
show sflow analyzer_server
Description
This command is used to display sFlow analyzer server information.
Format
show sflow analyzer_server
Parameters
None.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To display sFlow analyzer server information:
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...