![D-Link xStack DGS-3420 Series Скачать руководство пользователя страница 470](http://html.mh-extra.com/html/d-link/xstack-dgs-3420-series/xstack-dgs-3420-series_reference-manual_78239470.webp)
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
465
Chapter 40
IGMP Snooping
Multicast (ISM) VLAN
Commands
create igmp_snooping multicast_vlan
<vlan_name 32> <vlanid 2-4094> {remap_priority [<value
0-7> | none] {replace_priority}}
config igmp_snooping multicast_vlan
<vlan_name 32> {[add | delete] [member_port <portlist> |
[source_port <portlist> | untag_source_port <portlist>] | tag_member_port <portlist>] | state
[enable | disable] | replace_source_ip [<ipaddr> | none] | remap_priority [<value 0-7> | none]
{replace_priority}}(1)
create igmp_snooping multicast_vlan_group_profile
<profile_name 1-32>
config igmp_snooping multicast_vlan_group_profile
<profile_name 1-32> [add | delete]
<mcast_address_list>
delete igmp_snooping multicast_vlan_group_profile
[profile_name <profile_name 1-32> | all]
show igmp_snooping multicast_vlan_group_profile
{<profile_name 1-32>}
config igmp_snooping multicast_vlan_group
<vlan_name 32> [add | delete] profile_name
<profile_name 1-32>
show igmp_snooping multicast_vlan_group
{<vlan_name 32>}
delete igmp_snooping multicast_vlan
<vlan_name 32>
enable igmp_snooping multicast_vlan
disable igmp_snooping multicast_vlan
show igmp_snooping multicast_vlan
{<vlan_name 32>}
config igmp_snooping multicast_vlan forward_unmatched
[disable | enable]
config igmp_snooping multicast_vlan auto_assign_vlan
[enable | disable]
40-1
create igmp_snooping multicast_vlan
Description
This command is used to create an IGMP snooping multicast VLAN and implements relevant
parameters as specified. More than one multicast VLAN can be configured. Newly created IGMP
snooping multicast VLANs must use a unique VLAN ID and name, i.e. they cannot use the VLAN ID or
name of any existing 802.1Q VLAN. Also keep in mind the following conditions: multicast VLANs
cannot be configured or displayed using 802.1Q VLAN commands and the multicast VLAN snooping
function co-exists with the 802.1Q VLAN snooping function.
Format
create igmp_snooping multicast_vlan <vlan_name 32> <vlanid 2-4094> {remap_priority [<value
0-7> | none] {replace_priority}}
Parameters
<vlan_name 32>
- Specify the name of the multicast VLAN to be created. Each multicast VLAN is
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...