![D-Link xStack DGS-3420 Series Скачать руководство пользователя страница 191](http://html.mh-extra.com/html/d-link/xstack-dgs-3420-series/xstack-dgs-3420-series_reference-manual_78239191.webp)
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
186
Example
To test the cable on ports 1 to 4, and 8:
DGS-3420-28TC:admin# cable_diag ports 1:1-1:10,1:21
Command: cable_diag ports 1:1-1:10,1:21
Perform Cable Diagnostics ...
Port Type Link Status Test Result Cable Length (M)
------ ---------- ------------- ---------------------------- ------------
1:1 1000BASE-T Link Up OK 65
1:2 1000BASE-T Link Up OK -
1:3 1000BASE-T Link Down Shutdown 25
1:4 1000BASE-T Link Down Shutdown -
1:5 1000BASE-T Link Down Unknown -
1:6 1000BASE-T Link Down Pair 1 Crosstalk at 30M -
Pair 2 Crosstalk at 30M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:7 1000BASE-T Link Down NO Cable -
1:8 1000BASE-T Link Down Pair 1 Open at 16M -
Pair 2 Open at 16M
Pair 3 OK at 50M
Pair 4 OK at 50M
1:9 1000BASE-T Link Down Pair 1 Short at 5M -
Pair 2 Short at 5M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:10 1000BASE-T Link Down Pair 1 Unknown -
Pair 2 Short at 5M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:21 1000BASE-X Link Up Unknown -
DGS-3420-28TC:admin#
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...