![D-Link xStack DGS-3420 Series Скачать руководство пользователя страница 863](http://html.mh-extra.com/html/d-link/xstack-dgs-3420-series/xstack-dgs-3420-series_reference-manual_78239863.webp)
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
858
DGS-3420-28SC:admin#show sflow analyzer_server
Command: show sflow analyzer_server
sFlow Analyzer_server Information
------------------------------
Server ID : 1
Owner : admin
Timeout : 400
Current Countdown Time: 400
Collector Address :
Collector Port : 6343
Max Datagram Size : 1400
Total Entries: 1
DGS-3420-28SC:admin#
12-11
create sflow counter_poller ports
Description
This command is used to create the sFlow counter poller. With the poller function, the statistics
counter information with respect to a port will be forwarded to the server at the configured interval.
These counters are RFC 2233 counters.
Format
create sflow counter_poller ports [<portlist> | all] analyzer_server_id <value 1-4> {interval
[disable | <sec 20-120>]}
Parameters
<portlist>
- Specify the ports to be configured.
all
- Specify to configure all ports.
analyzer_server_id
- Specify the ID of an analyzer server where the packet will be forwarded.
<value 1-4>
- Specify the ID of an analyzer server where the packet will be forwarded.
interval
- (Optional) Specify the maximum number of seconds between successive statistic counters
information. If set to disable, the counter-poller is disabled. If the interval is not specified, its
default value is disable.
disable
- Specify to disable the interval.
<sec 20-120>
- Specify the interval, in seconds, between 20 and 120.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To create the sFlow counter poller:
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...