xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
996
DGS-3420-28SC:admin#
29-16
ping
Description
This command is used to send Internet Control Message Protocol (ICMP) echo messages to a remote
IP address. The remote IP address will then “echo” or return the message. This is used to confirm
connectivity between the switch and the remote device.
Format
ping [<ipaddr> | <domain_name 255>] {times <value 1-255> | timeout <sec 1-99> | source_ip
<ipaddr>}
Parameters
<ipaddr>
-
Specify the IP address of the host.
<domain_name 255>
- Specifies the domain name of the host. This name can be up to 255
characters long.
times
– (Optional) Specify the number of individual ICMP echo messages to be sent.
<value 1-255>
- Specify the number of individual ICMP echo messages to be sent. A value of 0
will send an infinite ICMP echo messages. The maximum value is 255. The default is 0
timeout
–
(Optional)
Specify the time-out period while waiting for a response from the remote device.
A value of 1 to 99 seconds can be specified. The default is 1 second.
<sec 1-99>
- Specify the time-out period while waiting for a response from the remote device. A
value of 1 to 99 seconds can be specified. The default is 1 second.
source_ip
- Specifies the source IP address of the ping packets. If specified, the IP address will be
used as the packets’ source IP address that ping send to remote host.
<ipaddr>
- Enter the source IP addres used here.
Restrictions
None.
Example
To send ICMP echo message to “10.51.17.1” for 4 times:
DGS-3420-28SC:admin#ping 10.51.17.1 times 4
Command: ping 10.51.17.1 times 4
Reply from 10.51.17.1, time<10ms
Reply from 10.51.17.1, time<10ms
Reply from 10.51.17.1, time<10ms
Reply from 10.51.17.1, time<10ms
Ping Statistics for 10.51.17.1
Packets: Sent =4, Received =4, Lost =0
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...