![D-Link xStack DGS-3420 Series Скачать руководство пользователя страница 373](http://html.mh-extra.com/html/d-link/xstack-dgs-3420-series/xstack-dgs-3420-series_reference-manual_78239373.webp)
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
368
parameter falls below this value, the action associated with the warning is taken.
<degrees>
- Enter the low threshold warning value here.
voltage_threshold
- Specify the threshold of optic module’s voltage.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<voltage>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<voltage>
- Enter the low threshold warning value here.
bias_current_threshold
- Specify the threshold of the optic module’s bias current.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<milliampere>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<milliampere>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<milliampere>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<milliampere>
- Enter the low threshold warning value here.
tx_power_threshold
- Specify the threshold of the optic module’s output power.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the low threshold warning value here.
rx_power_threshold
- Specify the threshold of optic module’s received power.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the low threshold warning value here.
state
- (Optional) Specify the DDM state to enable or disable. If the state is disabled, no DDM
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...