Parameters
<ipaddr>
- Enter the IP address of the server host.
port
- (Optional) The port number of the XTACACS server host.
<int 1-65535>
- Enter the value between 1 and 65535. The default value is 49.
timeout
- (Optional) Specify the time in second to wait for the server to reply.
<int 1-255>
- Enter the value between 1 and 255. The default value is 5.
retransmit
- (Optional) Specify the count for re-transmissions.
<int 1-20>
- Enter the value between 1 and 20. The default value is 2.
Restrictions
Only Administrator level can issue this command.
Example
To create a XTACACS server host:
DGS-3420-28SC:admin#create xtacacs server_host 10.1.1.224 port 15555 timeout 10
Command: create xtacacs server_host 10.1.1.224 port 15555 timeout 10
Success.
DGS-3420-28SC:admin#
4-47
config xtacacs server_host
Description
This command is used to configure a XTACACS server host.
Format
config xtacacs server_host <ipaddr> {port <int 1-65535> | timeout <int 1-255> | retransmit <int
1-20>}
Parameters
<ipaddr>
- Enter the IP address of the server host.
port
- (Optional) The port number of the XTACACS server host.
<int 1-65535>
- Enter the value between 1 and 65535. The default value is 49.
timeout
- (Optional) Specify the time in second to wait for the server to reply.
<int 1-255>
- Enter the value between 1 and 255. The default value is 5.
retransmit
- (Optional) Specify the count for re-transmissions.
<int 1-20>
- Enter the value between 1 and 20. The default value is 2.
Restrictions
Only Administrator level can issue this command.
Содержание xStack DGS-3420 Series
Страница 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Страница 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Страница 398: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 393 DGS 3420 28SC admin ...
Страница 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Страница 733: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 728 DGS 3420 28SC admin ...
Страница 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...