xStack
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch CLI Manual
203
config ddm ports
high_alarm
- Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<float>
- Enter the high threshold alarm value used here.
low_alarm
- Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<float>
- Enter the low threshold alarm value used here.
high_warning
- Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<float>
- Enter the high threshold warning value here.
low_warning
- Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<float>
- Enter the low threshold warning value here.
bias_current_threshold
- Specify the threshold of the optic module’s bias current.
high_alarm
- Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<float>
- Enter the high threshold alarm value used here.
low_alarm
- Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<float>
- Enter the low threshold alarm value used here.
high_warning
- Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<float>
- Enter the high threshold warning value here.
low_warning
- Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<float>
- Enter the low threshold warning value here.
tx_power_threshold
- Specify the threshold of the optic module’s output power.
high_alarm
- Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the high threshold alarm value used here.
low_alarm
- Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the low threshold alarm value used here.
high_warning
- Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<mw_or_dbm >
- Enter the high threshold warning value here.
low_warning
- Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<mw_or_dbm >
- Enter the low threshold warning value here.
rx_power_threshold
- Specify the threshold of optic module’s received power.
high_alarm
- Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<mw_or_dbm >
- Enter the high threshold alarm value used here.
low_alarm
- Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<mw_or_dbm >
- Enter the low threshold alarm value used here.
high_warning
- Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<mw_or_dbm >
- Enter the high threshold warning value here.
low_warning
- Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<mw_or_dbm >
- Enter the low threshold warning value here.
state
- Specify the DDM state to enable or disable. If the state is disabled, no DDM action will