D-Link DWS-1008 CLI Manual
1
Field
Description
Product Name
DWS model number.
System Name
System name (factory default, or optionally configured with
set system
name).
System Countrycode Country-specific 802.11 code required for AP operation.
(configured with
set system countrycode)
Total Power Over
Ethernet
Total power that the DWS-1008 is currently supplying to its directly connected
access points, in watts.
System Location
Record of the DWS switch’s physical location (optionally configured
with
set system location).
System Contact
Contact information about the system administrator or another person to
contact about the system (optionally configured with
set system contact).
System IP
Common interface, source, and default IP address for the DWS-1008, in
dotted decimal notation (configured with
set system ip-address).
System idle timeout
Number of seconds MSS allows a CLI management session (console, Telnet,
or SSH) to remain idle before terminating the session. (The system idle
timeout can be configured using the
set system idle-timeout command.)
System MAC
DWS-1008 media access control (MAC) machine address set at the factory,
in 6-byte hexadecimal format.
Boot Time
Date and time of the last system reboot.
Uptime
Number of days, hours, minutes, and seconds that the switch has been
operating since its last restart.
Fan status
Operating status of the three switch cooling fans:
• OK—Fan is operating.
• Failed—Fan is not operating. MSS sends an alert to the system log every
5 minutes until this condition is corrected. Fan 1 is located nearest the front
of the chassis, and fan 3 is located nearest the back.
Temperature
Status of temperature sensors at three locations in the DWS-1008 switch:
• ok—Temperature is within the acceptable range of 0° C to 50° C
(32° F to 122° F).
• Alarm—Temperature is above or below the acceptable range. MSS
sends an alert to the system log every 5 minutes until this condition is
corrected.
PSU Status
Status of the lower and upper power supply units:
• missing—Power supply is not installed or is inoperable.
• DC ok—Power supply is producing DC power.
• DC output failure—Power supply is not producing DC power. MSS
sends an alert to the system log every 5 minutes until this condition is
corrected.
• AC ok—Power supply is receiving AC power.
• AC not present—Power supply is not receiving AC power.
Содержание DWS-1008
Страница 1: ......
Страница 27: ...D Link DWS 1008 CLI Manual 24 ...