D-Link DWS-1008 CLI Manual
1
Defaults: By default, MSS allows nonsecure (unsecured) SNMP message exchanges.
Access: Enabled.
Usage: SNMPv1 and SNMPv2c do not support authentication or encryption. If you plan to use
SNMPv1 or SNMPv2c, leave the minimum level of SNMP security set to unsecured.
Examples: The following command sets the minimum level of SNMP security allowed to
authentication and encryption:
DWS-1008#
set snmp security encrypted
success: change accepted.
See Also:
• set ip snmp server
• set snmp community
• set snmp notify target
• set snmp notify profile
• set snmp protocol
• set snmp usm
• show snmp status
set snmp usm
Creates a USM user for SNMPv3.
Note: This command does not apply to SNMPv1 or SNMPv2c. For these SNMP versions, use
the
set snmp community command to configure community strings.
Syntax: set snmp usm
usm-username
snmp-engine-id {ip
ip-addr
| local | hex
hex-string
}
access {read-only | read-notify | notify-only | read-write | notify-read-write}
auth-type {none | md5 | sha} {auth-pass-phrase
string
| auth-key
hex-string
}
encrypt-type {none | des | 3des | aes} {encrypt-pass-phrase
string
|
encrypt-key
hex-string
}
usm-username
Name of the SNMPv3 user. Specify between 1 and 32 alphanumeric
characters, with no spaces.