ServiceTCPUDP
telnet
A "+" character in front of the row indicates that the object has been added. A "*" character indicates that the
object has been modified. A "-" character indicates that the object has been marked for deletion.
Web Interface
1.
Go to Configuration > View Changes in the menu bar
A list of changes is displayed
Activating and Committing a Configuration
After changes to a configuration have been made, the configuration has to be activated for those
changes to have an impact on the running system. During the activation process, the new proposed
configuration is validated and NetDefendOS will attempt to initialize affected subsystems with the
new configuration data.
Committing IPsec Changes
The administrator should be aware that if any changes that affect the configurations of
live IPsec tunnels are committed, then those live tunnels connections WILL BE
TERMINATED and must be re-established.
If the new configuration is validated, NetDefendOS will wait for a short period (30 seconds by
default) during which a connection to the administrator must be re-established. As described
previously, if the configuration was activated via the CLI with the activate command then a commit
command must be issued within that period. If a lost connection could not be re-established or if the
commit command was not issued, then NetDefendOS will revert to using the previous configuration.
This is a fail-safe mechanism and, amongst others things, can help prevent a remote administrator
from locking themselves out.
Example 2.10. Activating and Committing a Configuration
This example shows how to activate and commit a new configuration.
CLI
gw-world:/> activate
The system will validate and start using the new configuration. When the command prompt is shown again:
gw-world:/> commit
The new configuration is now committed.
Web Interface
1.
Go to Configuration > Save and Activate in the menu bar
2.
Click OK to confirm
The web browser will automatically try to connect back to the Web Interface after 10 seconds. If the connection
succeeds, this is interpreted by NetDefendOS that remote management is still working. The new configuration is
then automatically committed.
Note
The configuration must be committed before changes are saved. All changes to a
configuration can be ignored simply by not committing a changed configuration.
2.1.9. Working with Configurations
Chapter 2. Management and Maintenance
48
Содержание 800 - DFL 800 - Security Appliance
Страница 24: ...1 3 NetDefendOS State Engine Packet Flow Chapter 1 NetDefendOS Overview 24 ...
Страница 69: ...2 6 4 Restore to Factory Defaults Chapter 2 Management and Maintenance 69 ...
Страница 121: ...3 9 DNS Chapter 3 Fundamentals 121 ...
Страница 166: ...interfaces without an overriding IGMP Setting Default 1 000 4 6 4 Advanced IGMP Settings Chapter 4 Routing 166 ...
Страница 181: ...4 7 5 Advanced Settings for Transparent Mode Chapter 4 Routing 181 ...
Страница 192: ...5 5 IP Pools Chapter 5 DHCP Services 192 ...
Страница 282: ...6 7 Blacklisting Hosts and Networks Chapter 6 Security Mechanisms 282 ...
Страница 300: ...mechanism 7 3 7 SAT and FwdFast Rules Chapter 7 Address Translation 300 ...
Страница 301: ...7 3 7 SAT and FwdFast Rules Chapter 7 Address Translation 301 ...
Страница 303: ... Changed on a regular basis such as every three months 8 1 Overview Chapter 8 User Authentication 303 ...
Страница 318: ...8 3 Customizing HTML Pages Chapter 8 User Authentication 318 ...
Страница 322: ...ALG 9 1 5 The TLS Alternative for VPN Chapter 9 VPN 322 ...
Страница 377: ...Management Interface Failure with VPN Chapter 9 VPN 377 ...
Страница 408: ...10 4 6 SLB_SAT Rules Chapter 10 Traffic Management 408 ...
Страница 419: ...11 5 HA Advanced Settings Chapter 11 High Availability 419 ...
Страница 426: ...12 3 5 Limitations Chapter 12 ZoneDefense 426 ...
Страница 449: ...13 9 Miscellaneous Settings Chapter 13 Advanced Settings 449 ...