Parameter
Name
Description
Setting Range
1: User-Defined Parameter Access
Access to only parameter A1-01 and A2-00 to
A2-31
2: All Parameter Access
All parameters can be edited and viewed
A1-02 Control Method
Selection
0: Open-Loop V/F Control
1: Closed-Loop V/F Control
2: Open-Loop Vector Control
3: Closed-Loop Vector Control
4: PM Open-Loop Vector Control
5: PM Closed-Loop Vector Control
6: Closed-Loop Torque Control
7: Position Control
Default: 0
Min.: 0
Max.: 7
A1-03 Reset
Resets parameter settings to defaults. After
resetting parameters, the value will become 0.
2538: Resets 2-Wire Sequence/ 50Hz / 380V
2541: Resets 2-Wire Sequence / 50Hz / 415V
2544: Resets 2-Wire Sequence / 50Hz / 440V
2546: Resets 2-Wire Sequence / 50Hz / 460V
2638: Resets 2-Wire Sequence / 60Hz / 380V
2641: Resets 2-Wire Sequence / 60Hz / 415V
2644: Resets 2-Wire Sequence / 60Hz / 440V
2646: Resets 2-Wire Sequence / 60Hz / 460V
3538: Resets 3-Wire Sequence / 50Hz / 380V
3541: Resets 3-Wire Sequence / 50Hz / 415V
3544: Resets 3-Wire Sequence / 50Hz / 440V
3546: Resets 3-Wire Sequence / 50Hz / 460V
3638: Resets 3-Wire Sequence / 60Hz / 380V
3641: Resets 3-Wire Sequence / 60Hz / 415V
3644: Resets 3-Wire Sequence / 60Hz / 440V
3646: Resets 3-Wire Sequence / 60Hz / 460V
Default: 0
Range: 0 to 3646
A1-04 Password
Set password to parameter A1-05 and enter the
password to parameter A1-04 to unlock it.
Parameters A1-01 to A1-03, A1-06, A2-01 to
A2-32 cannot be edited until correct password
is entered to A1-04
Default
∶
0000
Min.: 0000
Max.: 9999
A1-05 Password Setting
A1-06 ND/HD Selection 0
∶
Heavy Duty (HD)
1
∶
Normal Duty (ND)
Default: 0
Range: 0, 1
A2: User-Defined Parameters
A2-00 to
A2-31
User-Defined
Parameters 1 to 32
Selects up to 32 parameters and assigns them
to parameter A2-00 to A2-31. Saved parameters Range: A1-00 to F1-18