background image

14

DC TO AC POW ER INV ERTER

    Part# PWRINV500036W

Instruction Manual

ON

OFF

Over Temp

r L

d

Ove   oa

T

R

BA TE Y

15

14

13

12

11

10

600

480

360

240

120

AIMS Operating Corp., Inc. dba AIMS Power Warranty Instructions:

This product is designed using the most modern digital technology and 
under very strict quality control and testing guide lines.  If however you 
feel this product is not performing as it should, please contact us:

[email protected] or (775)359-6703

We will do our best to resolve your concerns.  If the product needs repair 
or replacement, make sure to keep your receipt/invoice, as that will need 
to be sent back along with the package and RA# prepaid to AIMS.  You 
have a full 1 year from date of purchase warranty.

This warranty is valid world wide with the exception that freight and duty 
charges incurred outside the contiguous 48 United States will be prepaid 
by customer.

Except as provided above, AIMS makes no warranty of any kind, express 
or implied, including without limitation the implied warranties of 
merchantability and fitness for a particular purpose.  In no event shall 
AIMS be liable for indirect, special or consequential damages.  This 
warranty only applies to AIMS Power branded products.  All other name 
brand products are warranted by and according to their respective 
manufacturer.  Please do not attempt to return non-AIMS Power branded 
products to AIMS Power.

For additional products such as:
-Modified sine wave inverters
-Pure sine wave inverters
-Low Frequency Inverters
-Solar Charge Controllers
- On Grid Inverters
-Inverter Chargers and Automatic transfer switches
-Custom cut cables
-Batteries
-Solar Panels
Please visit our web site:  www.aimscorp.net

To find out where to buy any of our products, you may also e-mail:  
[email protected]  or call (775)359-6703.

Summary of Contents for PWRINV500036W

Page 1: ...t and duty charges incurred outside the contiguous 48 United States will be prepaid by customer Except as provided above AIMS makes no warranty of any kind express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no event shall AIMS be liable for indirect special or consequential damages This warranty only applies to AIMS Pow...

Page 2: ...emperature protection Efficiency Weight Input Voltage Range Low Voltage Alarm Output Surge Capacity Output Wave Form Switch OFF Switch ON No Load Current Draw Dimensions L x W x H PWRINV500036W 5000W 30 45V 570x210x180mm or 22 44 x8 26 x7 08 0 4 ADC 0 2 mADC Modified Sine Wave phase corrected 90 5 c 55 c 11KGS or 242 LBS 10000W DC 31 5V 1 5V DC 30V 1 5V ...

Page 3: ...Terminal Block Live Neutral Earth Remote MAX 1500W per outlet g AC TERMINAL BLOCK f REMOTE PORT No output voltage High input voltage Make sure that voltage indicator inverter in upper red zone is connected to 36V battery Check regulation of charging system ________________________________________________________ Low battery alarm Poor DC wirng poor Use proper cable on all the time battery conditio...

Page 4: ...ndow c Chassis grounding b Battery terminals X 11 Keep the cables between the battery and the power inverter as short as possible and twist them togerter with about 2 to 3 twists per foot This minimizes radiated interference from the cables 2 Troubleshooting guide ______________________________________________________ Problem and Symptoms Possible Cause Solution ___________________________________...

Page 5: ...capacitors in the power inverter Do not make this connection in the presence of flammable fumes as explosion or fire may result 3 10 The power inverter will also shut down if the input voltage exceeds 50V This protects the inverter against excessive input voltage The voltage indicator will be in the upper red zone Although the power inverter incorporates protection against overvoltage it may still...

Page 6: ...n any compartment capable of storing flammable liquids such as gasoline 4 9 the power delivered to the food not the power actually consumed by the microwave oven The microwave oven will consume 40 to 100 more than its advertised cooking power Check the rating sticker on the back of the oven to determine its actual power draw The 5000W inverter will operate small microwave ovens 0 2 to 0 3 cubic fo...

Page 7: ...tied to ground at the AC breaker panel 5 Ideally the voltage should remain in the green area of the bar graph If the voltage goes into the red area at the top or bottom of the graph the inverter may shut down 3 Battery current indicator The battery current bar graph indicates the current drawn from the battery by the power inverter It will not indicate current by other loads also connected to the ...

Page 8: ...verter When the switch is in the OFF position the power inverter draws no current from battery When the switch is in the ON position but with no load the power inverter draws less than 1 Amp 2 Battery voltage indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter At low input current this voltage is very close to the battery voltage At high input...