Parameter
Name
Description
Setting Range
L5:Torque Control
L5-00 Torque Command
Delay Time
Apply a filter with the time constant set to
parameter d5-02 to the torque reference signal
to eliminate oscillation resulting from an unstable
torque reference signal. Increase the setting
when oscillation occurs during torque control.
Default : 0 ms
Min.
∶
0 ms
Max.
∶
1000 ms
L5-01 Speed Limit
Selection
Selects the speed limit for Torque Control.
1 :Frequency Command
(b1-00 or b1-07)
2 :L5-02 and L5-03
Default
∶
1
Min.
∶
1
Max.
∶
2
L5-02 Forward Speed Limit
Sets the forward speed limit during Torque
Control as a percentage of highest speed when
L5-01 = 2.
Default
∶
10 %
Min.
∶
0 %
Max.
∶
120 %
L5-03 Reverse Speed Limit
Sets the reverse speed limit during Torque
Control as a percentage of highest speed when
L5-01 = 2.
Default
∶
10 %
Min.
∶
0 %
Max.
∶
120 %
L5-04
Speed/Torque
Control Switch
Delay Time
Sets the delay time for switching between Speed
Control and Torque Control.
Default
∶
0 ms
Min.
∶
0 ms
Max.
∶
1000 ms
L5-06
<7>
Torque Command
Delay Time 2
Apply a filter with the time constant set to
parameter d5-02 to the torque reference signal
to eliminate oscillation resulting from an unstable
torque reference signal. Increase the setting
when oscillation occurs during torque control.
Default
∶
10 ms
Min.
∶
0 ms
Max.
∶
1000 ms
L6: Offset Frequency
L6-00
<4> Offset Frequency 1
Sets the offset value as a percentage of the
maximum output frequency to add to or
subtract from the frequency command.
Select the offset frequency in E1-□□= 53, 54 and
55 (Offset Frequency 1 to 3).
Default: 0.0%
Min.: -100.0%
Max.: 100.0%
L6-01
<4> Offset Frequency 2
Sets the offset value as a percentage of the
maximum output frequency to add to or
subtract from the frequency command.
Select the offset frequency in E1-□□= 53, 54 and
55 (Offset Frequency 1 to 3).
Default: 0.0%
Min.: -100.0%
Max.: 100.0%
L6-02
<4> Offset Frequency 3
Sets the offset value as a percentage of the
maximum output frequency to add to or
subtract from the frequency command.
Select the offset frequency in E1-□□= 53, 54 and
Default: 0.0%
Min.: -100.0%
Max.: 100.0%