4.2 Main Circuit
4.2.1 Main Circuit Terminal
Table 4.2.1 Main Circuit Terminals
Terminal Name
Terminal Description
R/L1 (PV+),
S/L2 (PV-)
PV string input terminal
U/T1, V/T2, W/T3
3Ph power output terminal
B1, B2, +1, +2
Do not use in solar controller application
E
Ground terminal
4.2.2 Main Circuit Wiring
4.2.2.1 PV Input Terminal
Install a DC switch between PV string output and PV+/PV- terminal on controller. Surge
protector controller is also suggested to install.
Connect PV input wires from string PV+/PV- to DC swtich; DC switch to PV+/PV- terminal of
controller.
Ensure the max. voltage of PV will not over 750V at any condition, or may damage the
controller.
4.2.2.2 Power Output Terminal
Connect AC controller output terminals U/T1, V/T2 and W/T3 to loadinput terminals U, V and
W respectively. Ensure the loadand controller terminals are in same phase sequence or the
loadwill rotate reversely.