Installing the InformaCast Enabled Paging Adapter
Restore the Factory Default Settings
Operations Guide
931767B
CyberData Corporation
63
2. On the
Autoprovisioning
page, you may enter values for the parameters indicated in
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-14. Autoprovisioning Configuration Parameters
Web Page Item
Description
Disable Autoprovisioning
Prevent the device from automatically trying to download a configuration file. See
Section 2.5.12.1, "Autoprovisioning"
for more information.
Autoprovisioning Server
Enter the address of the provisioning server as a fqdn or IPv4 address in dotted
decimal notation.
Autoprovisioning Filename
The name of the configuration file. The default autoprovisioning filename is in the
format of
<mac address>.xml
.
Supported filename extensions are “.txt”, and “.xml.” The current filename is
denoted by an asterisk at the bottom of the
. Enter up to
256 characters.
A file may have any name with an xml extension. If a file name is entered, the
device will look for the specified file name, and only that file.
Use tftp
The device will use TFTP (instead of http) to download autoprovisioning files.
Username
The username used to authenticate with an autoprovisioning server. Leave this
field blank to disable authentication.
Password
The password used to authenticate with an autoprovisioning server. Leave this field
blank to disable authentication.
Autoprovisioning autoupdate
(in minutes)
The reoccurring time (in minutes) the device will wait before checking for new
autoprovisioning files. Enter up to 6 digits. A value of 0 will disable this option.
Note
: To use the auto update options, enable the
setting on the
Autoprovision at time (HHMMSS)
The time of day the device will check for a new autoprovisioning file. The time must
be 6 characters in length and in HHMMSS format. An empty value will disable this
option.
Note
: To use the auto update options, enable the
setting on the
Autoprovision when idle
(in minutes > 10)
The idle time (in minutes greater than 10) after which the device will check for a
new autoprovisioning file. Enter up to 6 digits. A value of 0 will disable this option.
Note
: To use the auto update options, enable the
setting on the
Click the
Save
button to save your configuration settings.
Click on the
Reboot
button to reboot the system.
Click on the
Toggle Help
button to see a short description of some of the web
page items. First click on the
Toggle Help
button, and you will see a question mark
(
) appear next to some of the web page items. Move the mouse pointer to hover
over a question mark to see a short description of a specific web page item.