Installing the InformaCast Enabled Paging Adapter
Restore the Factory Default Settings
Operations Guide
931767B
CyberData Corporation
57
shows the web page items on the
Events
page.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-13. Events Configuration
Web Page Item
Description
Enable Event Generation
The device will send HTTP POST events to the specified remote server and port
number whenever a certain action takes place. Select an event type below to
generate an HTTP POST event. See
Section 2.5.11.1, "Example Packets for
for sample packets.
Events
Enable Call Start Events
When selected, the device will report the start of a SIP call.
Enable Call Terminated Events
When selected, the device will report the end of a SIP call.
Enable Relay Activated Events
When selected, the device will report relay activation.
Enable Relay Deactivated Events
When selected, the device will report relay deactivation.
Enable Night Ring Events
When selected, the device will report when it starts ringing upon an incoming SIP
call to the Nightringer extension. As a reminder, the Nightringer extension always
rings upon an incoming SIP call and it is not possible to alter this behavior.
Enable Power On Events
When selected, the device will report when it boots.
Enable Fault Events
When selected, the device will report when the on-board fault detection is
activated.
Enable 60 Second Heartbeat
When enabled, the device will report a Heartbeat event every 60 seconds. SIP
registration is not required to generate Heartbeat events.
Enable Informacast Start Events
When selected, the device will report when a Start event has been received from
the Singlewire server.
Enable Informacast Stop Events
When selected, the device will report when a Stop event has been received from
the Singlewire server.
Event Server
Server IP Address
The IPv4 address of the event server in dotted decimal notation.
Server Port
Specify the event server port number. The supported range is 0-65536. Enter up
to 5 digits.
Server URL
Generally, the destination URL is the name of the application that receives the
events and the string in the HTTP POST command. It can be a script used to
parse and process the HTTP POST events. Enter up to 127 characters.
Check All
Click on
Check All
to select all of the events on the page.
Uncheck All
Click on
Uncheck All
to de-select all of the events on the page.
Click the
Save
button to save your configuration settings.
Click on the