Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Installation and assembly
32
6.7.7 Display and monitoring equipment
CAUTION!
All display and monitoring devices in a system that
is used for conveying explosive material must
comply with the Directive 2014/34/EC (ATEX) with
respect to equipment category, temperature class
and explosion group.
Vacuum meter, pressure gauge, temperature sensor, and flow
monitor must be installed for the safety of the VacuStar WR.
The process water supply in the reservoir must also be monitored.
We also recommend the installation of a speed counter.
Designation
Monitoring
parameters
Place of installation
Measuring range
Vacuum meter
Operating vacuum
Intended location,
immediate in front of
the inlet
0…1000 mbars
Pressure gauge
Positive working
pressure
Immediately after the
pressure pipe joint of
the VacuStar WR
0…2.0 bars
Temperature sensor
Compression end
temperature
After the pressure
flange
Up to approximately 120 °C
Flow monitor
Process water inlet
Water supply line
upstream of the
process water
connection of the
VacuStar WR
–
Water level indicator Water level in
VacuStar WR at
standstill
Exists ex-factory on
both lids
Only for visual inspection
Speed counter
(option)
Speed
Drive shaft
WR 2500 / WR 3100
WR 4000
800…1600 min
−
1
800…1300 min
−
1
Tab. 9: Display and monitoring equipment