Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Technical data
14
3.4 Technical data
General data
Unit
WR 2500
WR 3100
WR 4000
Nominal operating vacuum
1)
[mbar]
400
Angular momentum on the drive shaft
[kgm
2
]
1.40
1.80
3.9
Weight without water filling
[kg]
175
192
298
Permissible inclination to the side
[°]
22 (see Fig. 1, Fig. 2)
Permissible inclination in longitudinal direction
[°]
5
Process liquid
–
Water-glycol mixture
Tab. 1: General data
Permissible working range
Unit
WR 2500
WR 3100
WR 4000
Input speed
[1/min]
800 to 1600
800 to 1300
Suction temperature
1)
[°C]
-20…+60
Outlet temperature
[°C]
max. 65
Geodetic height
1)
[m]
0…1000
Maximum operating vacuum
4)
[mbar]
130
Maximum final overpressure with direct drive
3)
[bar]
1.5
1.5
1.0
Maximum final overpressure with V-belt drive
3)
[bar]
1.0
0.5
0.5
1) Consult CVS for suction temperature and/or altitudes outside the permissible working range.
2) Excess pressure = 0 bar, suction and ambient temperature = 20 °C
3) Vacuum = 0 mbar, suction and ambient temperature = 20 °C
4) Process water temperature = 20 °C
Tab. 2: Permissible working range