background image

SWIMMING POOL HEAT PUMP UNIT

Installation & Instruction Manual

Содержание OASIS Ci 10

Страница 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...

Страница 2: ......

Страница 3: ... Electrical Wiring 3 6 Initial Start up of the Unit 4 Operation and Use 4 1 4 2 4 3 4 4 5 Maintenance and Inspection 6 Appendix Installation illustration Swimming Pool Heat Pumps Location Color screen wire controller interface introduction Color screen wire controller function introduction Parameter list and breakdown table Interface drawin 6 2 Cable specification 6 1 Caution Warning 6 3 Explosive...

Страница 4: ...ccording to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant For split type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has follo...

Страница 5: ...onnection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight kW Btu h kW Btu h kW A W RPM dB A mm 3 m h kPa mm mm kg kg Nominal Heating Capacity By 50Hz Range KW A OASIS Ci 10 7 1 24140 2 85 12 0 9690 40800 0 21 2 12 0 9 9 2 230V 50Hz 1 rotary 1 100 400 800 horizontal 42 52 40 4 2 4 5 1051 410 767 1130 470 790 59 69 0 99 4 3 OA...

Страница 6: ... Dimensions L W H Net Weight Shipping Weight kW Btu h kW Btu h kW A W RPM dB A mm 3 m h kPa mm mm kg kg Nominal Heating Capacity By 50Hz Range KW A OASIS Ci 17 11 5 39100 4 6 19 5 15640 66300 0 37 3 94 1 6 17 1 230V 50Hz 1 rotary 1 120 500 900 horizontal 45 56 40 6 6 6 1163 447 868 1210 510 880 82 95 1 72 7 5 OASIS Ci 21 14 3 48620 5 7 24 2 19380 82280 0 46 4 8 2 0 20 9 230V 50Hz 1 rotary 2 200 40...

Страница 7: ...ool Heat Pump Unit OASIS Ci 10 unit mm unit mm Water inlet Φ40 Water outlet Φ40 350 100 1051 767 435 630 410 396 447 430 868 1163 470 815 Water inlet Φ40 Water outlet Φ40 A 100 2 SPECIFICATION 4 OASIS Ci 13 Model A OASIS Ci 17 400 470 ...

Страница 8: ...2 SPECIFICATION 5 2 2 The dimensions for Swimming Pool Heat Pump Unit Water inlet Φ40 Water outlet Φ40 470 100 OASIS Ci 21 OASIS Ci 25 unit mm 1163 1275 790 430 470 447 ...

Страница 9: ... time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe is higher than the pool surface 3 INSTALLATION AND CONNECTION Chlorinator cell Water outlet Pool Valve Water supply Water inlet Water pump Sand filter or other type filter The schematic diagram is for refere...

Страница 10: ...ous source of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 2 Swimming Pool Heat Pumps Location Normally the pool heat pump is installed within 7 5 metres of the pool The longer the distance from the pool the greater the heat loss from the piping For the most part the piping is buried Therefore the heat loss is minimal for runs of up to15 meters 15 meters to and fr...

Страница 11: ...to the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand and run to a suitable drain It is easy to mistake the condensation for a water leak inside the unit NB A quick way to verify that the water is condensation is to shut off the unit and keep the pool pu...

Страница 12: ...ime Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption Even a brief power interruption will activate the solid state 3 minute restart delay and prevent the...

Страница 13: ...on is green Click to turn on off silent function and to set timing Low speed function Click to view fault history Temp curve Silent setting Click to lock the screen Input 22 to unlock the screen by press the lock button 4 1 Color screen wire controller interface introduction 1 Main interface 2 Button Description Click to enter mode setting and the target temp Setting interface MODE Click to view t...

Страница 14: ...is designed for single automatic mode or single thermal mode the mode can not be switched 1 Booting and shutdown In shutdown status click then the unit will be booted In booting status click then the unit will be shut down As shown in figure 1 1 Click the temperature set button you can set the target temperature 2 2 1 Mode switch 2 2 Target temp setting In the main interface click mode button or i...

Страница 15: ...button interface displays as follows 3 Clock setting Click on the time Settings button interface displays as follows Note if the input format is not correct the wrong time will be saved by clicking confirm button For example setup time the 30 11 2016 16 00 00 input 30 11 16 16 00 00 the time change then click confirm button 3 1The operation of time setting ...

Страница 16: ...g start setting function Start green End gray Open red End gray Click this button to start or end timing end setting function Button color Timing star b tutton Timing on setting Timing end button Timing off setting Click to set end time of the timing NO Click to set start time of the timing Name When the timer was starting the clock button is green in the main interface ...

Страница 17: ...iming setting as follows Click the silent setting button and the interface displays 4 1 The silent button Click the silent button the unit will enter the silent mode and interface displays as follows Click the silent button again to exit the silent mode ...

Страница 18: ...o unuse the timing silent but if the unit is in timing silent mode it will exit silent timing immediately Click timing silent button and interface displays as follows Colur Use green Unused gray Used red Unused gray Function Click to use or unuse timing on function Click to use or unuse timing off function Click this button to set the timing silent start time Click this button to set the timing si...

Страница 19: ...ure record the main interface will display static if you check the failurerecord the main interface will displays static Failure record is in reverse order according to the happening time Press the Clean key you can delete the fault record When fault occurs the fault icon will flash between the the failure interface will record time code name of the fault Fault time day month year hour min The fau...

Страница 20: ... 6 2 The average power curve 2 6 1 Temperature recording curve is as follows Temperature curve automatically updates every one hour and the curve record can be stored for 60 days Start from the latest curve saved time if power is off and curve datacollecting time is less than one hour the data in this period will not be saved ...

Страница 21: ...Check or change the temp Sensor Check or change the temp Sensor Check or change the temp Sensor Check the pressure switch and cold circuit Check or change the temp Sensor Check the pressure switch and cold circuit check and replace this temp sensor Check whether fan motor is broken or locked or not Inlet Temp Sensor Fault PP Pressure sensor Fault The temp Sensor is broken or short circuit The temp...

Страница 22: ...ng voltage check requency conversion board hardware Check whether current return wires connected motor Check and adjust the current measurement Check the input voltage measurement Check the input voltage measurement Check the input voltage measurement Check the input voltage measurement Check and adjust the current measurement Check the communication connection Check the PFC switch tube short circ...

Страница 23: ... Default Refrigeration target temperature set point Heating the target temperature set point Automatic target temerature set point 4 OPERATION AND USE AC L OUT1 OUT2 OUT3 AC N OUT4 OUT5 PC1002 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND 0 10V OUT AI DI01 AI DI03 AI DI04 AI DI05 AI DI06 AI DI07 AI DI08 AI DI09 AI DI10 AI DI11 AI DI02 AI12 50K 0 5V IN PWM IN PWM OUT 5V 12...

Страница 24: ...20 230VAC Low speed of fan output 220 230VAC Live wire input 220 230VAC Neutral wire input 220 230VAC Emergency switch input Water flow switch input System low pressure input System high pressure input Water output temperature input System fan coil temperature input Ambient temperature input Mode switch input Master slave machine switch Antifreeze temperature input System Exhaust temperature input...

Страница 25: ...serve energy The operation pressure of the refrigerant system should only be serviced by a certified technician Discharge all water in the water pump and water system so that freezing of the water in the pump or water system does not occur You should discharge the water at the bottom of water pump if the unit will not be used for an extended period of time You should check the unit thoroughly and ...

Страница 26: ...handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs This product is compliant with directive 2002 95 EC RoHs concerning restrictions for the use of harmful substances in electric and electronic devices 7 The unit CANNOT be installed near the fl...

Страница 27: ...epage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm 2 mm 25 2 mm 25 2 35mm 2 50mm 2 70mm 2 95mm 2 Three phase unit 2 3 1 5mm 2 3 2 5mm 2 3 4mm 2 3 6mm 2 3 10mm 2 16mm 3 2 25mm 3 2 3 25mm 2 3 35mm 2 3 50mm 2 3 70mm 2 3 95mm 30mA less than 0 1 sec 30mA less than 0 1...

Страница 28: ...Model and code OASIS Ci 10 A 6 APPENDIX 25 6 3 Explosive view of the unit ...

Страница 29: ... Pipe Needle reducing straight way reducing straight way Filter pressure switch pressure switch check valve 4 way Valve and fittings Electronic Expansion Valve electronic box compressor right panel flow switch top cover heat exchanger Electrical Box Cover Supporting Plate back protection net titanium heat exchanger Middle Plate Fan Motor Support Fan Blade Fan Guard fan motor fan protection net Fro...

Страница 30: ...27 6 APPENDIX Model and code OASIS Ci 13 A ...

Страница 31: ...sure sensor Needle Needle Filter pressure switch pressure switch 4 way Valve and fittings Electronic Expansion Valve electronic box compressor right panel flow switch top cover heat exchanger Electrical Box Cover Supporting Plate back protection net titanium heat exchanger Middle Plate Fan Motor Support Fan Blade Fan Guard fan motor fan protection net Front Plate Colorful display Chassis Pc1002 In...

Страница 32: ...29 Model and code OASIS Ci 17 6 APPENDIX A ...

Страница 33: ...dle T Pipe Colorful display reducing straight way Chassis Filter pressure switch pressure switch check valve 4 way Valve and fittings Electronic Expansion Valve electronic box compressor right panel flow switch top cover heat exchanger Electrical Box Cover Supporting Plate back protection net titanium heat exchanger Middle Plate Fan Motor Support Fan Blade Fan Guard fan motor fan protection net Fr...

Страница 34: ...31 Model and code OASIS Ci 21 1 2 3 4 6 5 8 7 10 9 11 14 12 13 15 16 17 18 19 21 20 22 23 25 24 26 27 29 28 30 31 32 33 34 35 36 37 38 6 APPENDIX ...

Страница 35: ...Check valve fluid reservoir Electric box lining board Front Plate Colorful display fan protection net Fan Guard Fan Blade back protection net fan motor heat exchanger Fan Motor Support Supporting Plate top cover Electrical Box Cover Middle Plate Electrical Box flow switch right panel Needle Needle Needle pressure switch pressure switch 4 way Valve and fittings T Pipe Filter Electronic Expansion Va...

Страница 36: ...33 Model and code OASIS Ci 25T 6 APPENDIX 44 45 46 1 2 3 4 6 5 8 7 10 9 11 15 12 13 16 17 18 19 21 20 23 25 24 26 28 31 29 32 33 34 14 22 27 30 35 36 37 38 39 40 41 42 43 ...

Страница 37: ...h p Low p W Check valve Junction e v Pressure sensor T C Fluid reservoir I Electric box lining board b b Terminal Terminal Terminal plate Three phase filter ZL10 V3 Three phase ac monitor Front late Colorful display an protection net Fan uard Fan lade ack protection net an motor eat exchanger Fan otor upport Supporting late op cover Electrical ox over Middle late Electrical ox Electrical box 2 flo...

Страница 38: ...Note ...

Страница 39: ......

Страница 40: ...Code 20170818 0002 ...

Отзывы: