22
Check the water supply device and the release often. You should avoid the condition of no
water or air entering into system, as this will influence unit's performance and reliability.
You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the
dirty of clogged filter.
The area around the unit should be dry, clean and well ventilated. Clean the side heating
exchanger regularly to maintain good heat exchange as conserve energy .
The operation pressure of the refrigerant system should only be serviced by a certified
technician .
Discharge all water in the water pump and water system ,so that freezing of the water in the
pump or water system does not occur. You should discharge the water at the bottom of
water pump if the unit will not be used for an extended period of time. You should check the
unit thoroughly and fill the system with water fully before using it for the first time after a
Check the power supply and cable connection often,.Should the unit begin to operate
abnormally, switch it off and contact the qualified technician.
5. MAINTENANCE AND INSPECTION
21
4.OPERATION AND USE
Main board of the input and output interface instructions below
OUT1
OUT2
OUT3
OUT4
OUT5
AC-L
AC-N
AI/DI01
AI/DI02
AI/DI03
AI/DI04
AI/DI05
AI/DI06
AI/DI07
AI/DI08
AI/DI09
AI/DI10
AI/DI11
AI12(50K)
0_5V_IN
PWM_IN
PWM_OUT
0_10V_OUT
+5V
+12V
GND
485_B1
485_A1
12V
GND
485_B2
485_A2
12V
CN9
Sign
Meaning
Number
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Compressor ( output 220-230VAC)
Water pump ( output 220-230VAC)
4-way valve ( output 220-230VAC)
High speed of fan ( output 220-230VAC)
Low speed of fan (output 220-230VAC)
Live wire ( input 220-230VAC)
Neutral wire ( input 220-230VAC)
Emergency switch
input
Water flow switch
input
System low pressure
input
System high pressure
input
Water output temperature ( input )
System fan coil temperature( input)
Ambient temperature( input)
Mode switch
input
Master-slave machine switch / Antifreeze
temperature(input)
System Exhaust temperature (input)
Compressor current detection/Pressure sensor(input)
Master-slave machine switch / Feedback signal of EC
fan ( input )
AC fan control ( output )
EC fan control ( output )
+5V ( output )
+12V ( output )
(
)
(
)
(
)
(
)
System suction temperature (input)
Water input temperature (input)
(
)
Frequency conversion board communications
Color line controller communication
Electronic expansion valve
Содержание OASIS Ci 10
Страница 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...
Страница 2: ......
Страница 28: ...Model and code OASIS Ci 10 A 6 APPENDIX 25 6 3 Explosive view of the unit ...
Страница 30: ...27 6 APPENDIX Model and code OASIS Ci 13 A ...
Страница 32: ...29 Model and code OASIS Ci 17 6 APPENDIX A ...
Страница 38: ...Note ...
Страница 39: ......
Страница 40: ...Code 20170818 0002 ...