Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Start-up
40
7.3 Switching off
To switch off the VacuStar WR, proceed as follows:
Switch off drive for the VacuStar WR
Close the shut-off valves (if installed)
Drain the safety tank. Vessel may not be in a state of vacuum
when condensate is drained.
7.4 Inspections to be performed
pH value of the process water
Depending on the conveyed medium, the steady water
delivery can lead to an increased concentration of harmful
substances and thus to a change in the pH value.
The permissible pH value (see page 16, Tab. 5) must be
checked (using litmus paper, for example) at regular
intervals according to the operation experience.