Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Technical data
15
VacuStar WR performance data vacuum
operation
Unit
WR 2500
WR 3100
WR 4000
Suction pressure: 400 mbar
1), 2)
Speed
[1/min]
1600
1300
Maximum intake volume flow
1), 2), 3)
[m
3
/h]
2500
3100
4063
Coupling power
1), 2), 3)
[kW]
73
88
117
Intake volume flow
1), 2)
[m
3
/h]
2016
2427
3521
Coupling power
1), 2)
[kW]
61
76
107.5
Sound pressure level at 7 m distance at
400 mbar
[dB(A)]
70
72
73
1) Excess pressure = 0 bar, suction and ambient temperature = 20 °C
2) Process water temperature = 20 °C
3) Water vapour saturated air = 55 °C
Tab. 3: Performance data vacuum operation
VacuStar WR performance data
pressure operation
Unit
WR 2500
WR 3100
WR 4000
Excess pressure: 0.5 bar
1), 2)
Coupling power
[kW]
77
94
131.5
Intake volume flow
[m
3
/h]
1936
2469
3496
Sound pressure level at 7 m distance
at 0.5 bar excess pressure
[dB(A)]
70
72
73
1) Vacuum = 0 mbar, suction and ambient temperature = 20 °C
2) Process water temperature = 20 °C
Tab. 4: Performance data pressure operation