Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Design and function
17
4 Design and function
4.1 Design
Fig. 5: Design
1 Drive shaft
2 Connection process water
3 Cell ventilation connection
4 Connecting flange for pressure or suction
connection (flange DIN 28459)
5 Process water draining
6 Rating plate
7 Rotation arrow
8 Thread for eye bolt
9 Fixing foot
10 Water level indicator
11 Liquid supply for slide ring seal
12 Manuel fill level inspection
4.2 Function
VacuStar WR
The liquid ring pump works according to the positive displacement
principle. At a sufficiently high speed, a rotating liquid ring is
formed in the casing. In conjunction with the impeller, cells form
that are separated from each other and steadily grow (sucking) or
shrink (compressing) with each revolution.