Mounting instructions VacuStar WR 2500 / WR 3100 / WR 4000
Installation and assembly
25
6.3 Necessary work
Installation requires the following activities:
Installing all components on the vehicle side.
Installing VacuStar WR with suction and pressure lines.
Installing safety and monitoring equipment.
Connecting the VacuStar WR with the process water
circulation.
Connecting the drive with VacuStar WR. Observe sense of
rotation and speed range.
6.4 Assembly of the VacuStar WR
Fixing options for the VacuStar WR
Four screws at the feet of the VacuStar WR secure the
VacuStar WR to the vehicle.
To adjust the unit in the best possible way to the installation
conditions, the feet of the VacuStar WR can be rotated
clockwise or anticlockwise by one screw pitch. See page 11,
Fig. 1 and page 12, Fig. 2
Checking the function before the
installation
Check the rotor shaft function. Rotating the rotor shaft with
your hand must be possible.
Requirements
placed upon installation point
and attachment
The attachment points on the vehicle must feature a
sufficient load capacity and rigidness.
The attachment points for the feet of the VacuStar WR must
be on the same level.
Requirements
upon the installation location
Protected against dirt, gravel impact and splashing water.
offer sufficient space for accidental contact protection.
offer sufficient space for the connections of the suction and
pressure lines.
ensure good legibility of the instruments.
Accessible for maintenance and repair work (e.g. for
replacing the air filter, or for checking the safety and non-
return valve).
Assembly
Use the following screws for securing the VacuStar WR:
Model
Screw
Solidity
Torque
WR 2500 / 3100
M16
8.8
190 Nm
WR 4000
M24
8.8
680 Nm
Tab. 6: Fastening screws