Series M2 Specifications
5
Cat. No. 01023095
Series M2 Specifications
NOTE
The International Specifications for M2 are in
M2-2
M2-3
M2-4
M2-5
M2-6
Nominal Capacity, GPD*
4000
5800
7500
9000
10000
Dimensions, Series M2 Units
Width - in [mm]
25.8 [655.3]
Depth - in [mm]
29.3 [744.2]
Height - in [mm]
52.6 [1336]
Operating Weight lb [kg]
198 [89.1]
228 [102.6]
258 [116.1]
288 [129.6]
318 [143.1]
Unit Connections
Inlet (NPT)
0.75"
Product (Tube)
0.5"
Concentrate (Tube)
0.5"
Electrical
Motor Horsepower (hp)
1.0
Power Requirement (VAC/Hz/phase)
208–230/60/1
Full Load Current (amp)
3.4-3.7
Hydraulic - Prefilter
Housing Quantity
2
3
4
5
6
Cartridge Quantity
1
Cartridge Size - in [mm]
10 [254]
Cartridge Rating (micron)
5
Hydraulic - RO
RO Housing Quantity
2
3
4
5
6
RO Element Quantity
2
3
4
5
6
RO Element Length - in [mm]
40 [1016]
40 [1016]
40 [1016]
40 [1016]
40 [1016]
Product Flow - gpm [L/min]*
2.78 [10.52]
4.03 [15.25]
5.21 [19.72]
6.25 [23.66]
6.94 [26.29]
Concentrate Flow - gpm [L/min]*
2.78 [10.52]
2.69 [10.16]
3.47 [13.14]
2.08 [7.89]
2.31 [8.76]
Recovery (%)*
Design
50
60
60
75
75
Minimum
40
50
50
60
60
Maximum Module Feed Pressure psig [kPa]
160 [1103]
Nominal Module Feed Pressure psig [kPa]
140 [965]
Maximum Product Pressure psig [kPa]
40 [276]
Operating Temperature °F [°C]
40–100 [4–38]
Inlet Pressure
Minimum, dynamic psig [kPa]
15 [103]
Maximum, dynamic psig [kPa]
40 [276]
Maximum, static psig [kPa]
100 [689]
Required Inlet Feed Flow gpm [L/min]
5.56 [21.0]
6.71 [25.4]
8.68 [32.9]
8.33 [31.5]
9.26 [35.1]
Pump Flow @ 125 psi gpm [Lmin]
11.0 [41.6]
11.0 [41.6]
11.0 [41.6]
11.0 [41.6]
11.0 [41.6]
Salt Rejection, Nominal (%)
97
97
97
96
95
†Calculated using a 0.85 fouling factor
*Nominal capacity based on new RO membranes operating on a properly pretreated feed water of 500 ppm TDS as NaCl,
77 °F (25 °C), Silt Density Index (SDI) below 3, and supplying water to atmosphere. Productivity will vary depending on
the actual feed water quality and temperature.