Setup
27
Cat. No. 01023095
Screen Display
Range
Procedure
FLOW TRIG MODE
OFF
Off
On
14. The screen displays the Flow Trigger Mode setting. Press
or
and then
to change the value and see the flow
trigger mode settings.
FLOW TRIG MODE
OFF
Off
On
15. The screen displays the Flow Trigger Mode setting. If the sys-
tem is running, the unit will flush after generating a specified
amount of reverse osmosis water. Press
or
and
then
to change the value if necessary.
FLUSH DURATION
3
MINUTES
1–180
16. If flow trigger mode is set to ON, the screen displays the flush
duration setting. Press
or
and then
to change
the value and then display the next setting.
FLUSH EVERY
100
GALLONS
100–1000
17. If flow trigger mode is set to ON, the screen displays the flush
interval setting. Press
or
and then
to change
the value and then return to the Flush Mode menu.
QUAL FLUSH MODE
DISABLE
Disable
18. The screen displays the Quality Flush Mode setting. When the
system is running, the system sends all water to drain until a
preset quality is reached, at which time the water will flow to
the product outlet. This is a high pressure flush (pump is on).
The quality flush mode is disabled and can not be changed.
Press any button to return to the Flush Mode menu.
PERM FLUSH
OFF
Off
On
19. The screen displays the Permeate Flush setting. This flush
requires an optional solenoid valve and permeate storage tank
from where the flush water is drawn. Press
or
and
then
to change the value if necessary.
FLUSH DURATION
10
SECONDS
1–180
20. If permeate flush mode is set to ON, the screen displays the
flush duration setting. Press
or
and then
to
change the value and then display the next setting.
RUNNING
JAN-01-12 12:01P
21. Press
to return to the home screen.