50
Culligan® Series M2 Reverse Osmosis
50
Cat. No. 01023095
Multi-RO Unit Settings
RUNNING
JAN-01-12 12:01P
1. From the default home screen, press
. The screen displays the main menu.
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
2. Press
to scroll to 4) SETUP.
3. Press
to select the SETUP menu.
2) LANGUAGE
3) POWERON MODE
4) FLUSH MODES
>5) ACCESSORIES
4. Press
to select 5)ACCESSORIES. The screen displays the ac-
cessories menu.
5) PRESS GAUGES
6) TDS
7) RELAY MODE
>8) MULT UNIT RO
5. Press
to select 8)MULT UNIT RO. The screen dis-
plays the multiple unit RO settings.
Screen Display
Range
Changing the Setting
MULTI UNIT RO
SINGLE
Single
Two Pass RO
Alternating
Press
or
and then
to select the RO system
configuration.
MUL UNIT RO ROLE
MASTER
Master
Slave
If you select Two-Pass RO or Alternating, press
or
and
then
to select MASTER if the selected RO will control the func-
tions of the entire RO system. Select SLAVE if the selected RO will
be controlled by the master RO.
Operating System Information for a Two-Pass RO
Once the units are set for “TWO PASS RO”, only the Master unit can be used to change or access information. The Slave
unit will only state whether or not the motor for the slave is on or off, see the screen shot below.
SECOND PASS
Motor ON
Motor ON
Motor OFF
This screen shows the status of the Slave unit/ Second Pass’s
motor.
The following screen shots can ONLY be viewed on the Master unit/ First Pass.
1)GO TO RUNNING
2)GO TO OFFLINE
>3)INFORMATION
4)SETUP
1. Press
to select 3)INFORMATION.