background image

 34 

 

Culligan® Series M2 Reverse Osmosis

 34 

 

Cat. No. 01023095

GROC Modem Settings

Screen Display

Range

Changing the Setting

TELEPHONE MODEM 

INSTALLED

Installed, 

Not 

Installed

Press 

  

 or 

 and then 

 to select INSTALLED if a telephone modem 

is installed inside the Smart Controller. 

MODEM CONNECTION 

LANDLINE

LandLine

CellModem

Press 

  

 or 

 and then 

 to change the Modem connection setting. 

See the note on the previous page about analog and digital phone lines.

MODEM LOCATION 

IN MAIN CONTROL

In Main 

Control

In Remote

Press 

  

 or 

 and then 

 to change the Modem Location setting. 

Change this setting only if a modem is installed.

TIME zONE GMT

+00:00

0 to +12 or 

-12

Press 

  

 or 

 and then 

 to specify the time zone of the RO Controller 

location with respect to Greenwich Mean Time (GMT).
When using a modem, the controller will occasionally access the Internet to 

synchronize the date and time. In order to do this correctly, the control must 

be told which time zone it is installed in. The time zone is specified as so many 

hours ahead or behind GMT time. The GMT offset for some common cities is 

listed below:

GMT Offset

New York 

-5:00 (and anywhere in EST)

Chicago 

-6:00 (CST)

Denver 

-7:00 (MST)

Los Angeles 

-8:00 (PST)

London 

0:00

Paris 

0:00

Rome 

+1:00

CALL FREQUENCY 

DAILY

Daily

On Error

Daily&Error

Monthly & 

Error

Press 

  

 or 

 and then 

 to specify the frequency of the RO controller 

sending data via modem.  

CALL TIME 

4:30AM

12:00AM–

11:30PM Press      or   and then   to specify when the RO controller sends data 

via modem.  The time changes in increments of 30 minutes.

Содержание M2 Series

Страница 1: ...Series M2 Reverse Osmosis Water Treatment Systems Models from 2011 Firmware Version 2013 Culligan International Com pa ny Installation Operation and Service Instructions Cat No 01023095 Rev C 05 03 13 DCO 013581 ...

Страница 2: ...rt 15 of the FCC rules subject to the two following conditions 1 This device may not cause harmful interference and 2 This device must accept all interference received including interference that may cause undesired operation This equipment complies with Part 15 of the FCC rules Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the e...

Страница 3: ...Programming 15 Menu and Key Navigation 16 First Time Set Up 17 Basic Operation 20 Setup 21 Accessories 28 Initial Startup 55 System Operating Information 58 Service and Maintenance 60 Flow Diagram 71 GBE RO Controller Wiring 72 M2 RO Parts Diagrams and Lists 73 Appendix A Series M2 International 87 Appendix B Basic Principles 102 Appendix C GBE RO Controller Menu Structure 104 Appendix D Data Port...

Страница 4: ...ii Culligan Series M2 Reverse Osmosis ii Cat No 01023095 This page intentionally left blank ...

Страница 5: ...ments could cause changes that may not be included in this publication Safe Practices Throughout this manual there are paragraphs set off by special headings Notice Notice is used to emphasize installation operation or maintenance information which is important but does not present any hazard For example NOTICE The nipple must extend no more than 1 inch above the cover plate Caution Caution is use...

Страница 6: ...rm Output Connection Optional Provides either a N O or N C Dry Contacts This feature can be used to activate an alarm or programmed into a customers DCS building alarm system GBE RO Controller GROC Features System Computes Normalized Flow The system computes normalized flow and can be set to trigger an alarm if the normalized flow drops below a specified limit Power Up Mode The system can be confi...

Страница 7: ...rmation and convert the data for their data collection system For more information see Culligan P N 01021512 Advanced Communication Manual This data once converted from a text stream can easily be imported to an excel spreadsheet and the data logged can then be graphed and trended Multi Unit RO The GBE RO controller supports two multi unit modes Two Pass and Duplex Alternating When in two pass or ...

Страница 8: ...er s own PLC for data collection or monitoring The Errors and historical data are listed below Customer would have to write code to take text information and convert the data for their data collection system Data Stream Available RO Status Running Standby or Offline All current Error Flags listed above Most recent feed flow in GPM Most recent product flow in GPM Total product gallons produced in g...

Страница 9: ...6 40 1016 Product Flow gpm L min 2 78 10 52 4 03 15 25 5 21 19 72 6 25 23 66 6 94 26 29 Concentrate Flow gpm L min 2 78 10 52 2 69 10 16 3 47 13 14 2 08 7 89 2 31 8 76 Recovery Design 50 60 60 75 75 Minimum 40 50 50 60 60 Maximum Module Feed Pressure psig kPa 160 1103 Nominal Module Feed Pressure psig kPa 140 965 Maximum Product Pressure psig kPa 40 276 Operating Temperature F C 40 100 4 38 Inlet ...

Страница 10: ...ations An M2 6 unit is pictured in Figure 1 See M2 RO Parts Diagrams and Lists on page 73 for a list of component part numbers Membranes Product Flow Meter RO Controller GROC Pump Pump Feed Pressure Prefilter Recirculation Control Waste Control Figure 1 M2 RO front view ...

Страница 11: ...s the dimensions Note that these figures do not account for working space around the unit and the space for plumbing connections NOTICE The installer is responsible for the power supply to the unit The steel frame is designed to distribute the operating weight on an even floor space If the floor is uneven grout beneath the steel frame feet so that the unit is evenly supported Secure the base of th...

Страница 12: ... For 3 D tube fitting diagrams see the parts section starting on page 79 CENTER PORT OF END CAPS CENTER PORT OF END CAPS CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS Figure 2 Module Tubing two to four membranes ...

Страница 13: ...9 Cat No 01023095 CENTER PORT OF END CAPS CENTER PORT OF END CAPS CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS OFF CENTER PORT OF END CAPS Figure 3 Module Tubing five or six membranes ...

Страница 14: ...m the outlet of the unit 2 To prevent siphoning of the water in the unit to drain raise the concentrate plumbing above the level of the modules and provide an anti siphon loop WARNING An air gap must be provided between the end of the concentrate tubing and the drain to prevent back siphoning of drain contents Product Water Connections The product water exits on the pump side of the unit in either...

Страница 15: ... be required Direct Feed If the product water is to be used directly without storage a few precautions are necessary to prevent damage to the elements Install a pressure gauge pressure relief valve and a normally open dump solenoid in the product water line as shown in Figure 4 The pressure gauge will allow the operator to monitor the product water pressure The relief valve which should be set to ...

Страница 16: ...nections DO NOT include the GROC wiring cables in any conduit or raceway containing other 120 volt or higher circuits Maintain a distance of at least 10 feet between the GBE controller and any electrical distribution panels raceways carrying 300 volts or more Use the cabling provided Failure to do so may affect performance of the GBE controller adversely Series M2 Electrical Installation To open t...

Страница 17: ...2 Keypad connector Battery CR2032 Postitive Side Up OLED display Figure 6 GROC circuit board layout front P N XXXXXXXX rev X VENDOR XXXXXX DATE CODE WK YY HEX FILE XXXXXXXX rev X Power Hi and Lo Float Switches J12 Inlet Flow Meter J13 MT Board J20 Remote Display RF Board Connector Modem Connectors Aux Board Product Flow Meter J1 Pressure Switch and Pretreat Lockout J2 24VAC Figure 7 GROC circuit b...

Страница 18: ...s 14 Cat No 01023095 NOTE For Series M2 RO Systems make sure the voltage selector switch is set at 230 VAC 115 230 Voltage Selector Switch Transformer Fuse 315mA Power 115V 230VAC 50 60Hz Fuse 5A Relays Figure 8 GBE 115V 230V relay board ...

Страница 19: ... invalid three beeps key presses The beeper can be deactivated in the programming mode If error occurs beep will still sound even if set to No programming Programming Mode Timeout If there is no keypad activity for a one 1 minute period while in the programming mode the controller will exit the programming mode and return to the main display Any setting that was changed prior to the control timing...

Страница 20: ...own the menu CHECK MARK button selects the highlight ed option opens a new screen or accepts a changed setting CANCEL or EXIT button returns to the pre vious screen or cancels a changed setting NOTE Hold down the or button to quickly scroll through the setting without repeatedly pressing the button CAUTION Use the and only to scroll through the menu settings Do not use to perform scrolling Imprope...

Страница 21: ...the screen displays FIRST TIME SETUP Press S N 00012345 FWR LT04 MON DD YEAR 2 The screen displays the serial number and firmware version and date installed for this GROC Press to accept this information The screen displays the first set ting month NOTE The S N firmware and date displayed in this manual are examples only NOTE If this unit will be installed with a modem it is required that this ele...

Страница 22: ...tting Press or and then to change the value and see the next setting SET HOUR 12PM 12AM 11PM 4 The screen displays the hour setting Press or and then to change the value and see the next setting SET MINUTES 25 0 59 5 The screen displays the minutes setting Press or and then to change the value and see the next setting POWERON MODE OFFLINE Running Offline 6 The screen displays the selected status o...

Страница 23: ...O controller so that users will only have access to the INFORMATION GO TO RUNNING and GO TO OFFLINE menu screens To lock the system press and hold and for 10 seconds Repeat this process to unlock the keypad NOTE Menu lockout may be completed only from the home screen Menu Default Rerun First Time Setup Below is the procedure to default the board to factory settings and begin the first time setup 1...

Страница 24: ...e to YES if you want the system to start running select NO to cancel the command and return to the main menu STARTING JAN 01 12 12 01P STARTUP FLUSH 4 The screen displays the status of the unit as it initiates the startup process RUNNING JAN 01 12 12 01A 5 The home screen displays the operational status RUNNING Go To Offline 1 Go to running 2 go to offline 3 information 4 setup 1 Press to select 1...

Страница 25: ... Inputs Pressure Transducers G2 G3 only Setup Accessories Press Gauges System Setup Set Up Time Date If the unit loses time for some reason you can use this setting to reset the correct date and time Please note that if you have a modem installed and connected to the phone line the unit will check for the correct time each time it calls in running jan 01 12 12 01P 1 From the default home screen pr...

Страница 26: ...YLIGHT SAVING YES YES NO 7 The screen displays whether you observe daylight savings time where the RO unit is installed Press or and then to change the value and return to the Time Date menu running jan 01 12 12 01P 8 Press to return to the home screen Set Up Language Use the language setting to change the displayed language on the RO controller NOTE Ensure the units of measure US Metric are appro...

Страница 27: ...er power is supplied OFFLINE The RO system will go into standby when power is sup plied to the unit running jan 01 12 12 01P 6 Press to return to the home screen Flush Modes The GBE RO controller can be programmed to operate up to six different flush modes Multiple flush modes can be speci fied and operating at any one time If any one or more flush modes are calling for flushing to happen at a cer...

Страница 28: ...ush sole noid valve is wired to the AUX board on the GBE RO controller at terminal AUX4 The solenoid valve must be 24 VAC 7R 6HUYLFH 69 7 6 QOHW 9DOYH 69 3XPS UDLQ 0 0 5 1 286 1 6 Figure 9 RO quality flush At startup SV1 opens and then the pump turns on SV3 opens while the system monitors the product TDS level The user programs the maximum allowable product TDS and the number of minutes allowed fo...

Страница 29: ...ate Off Closed Open Open Table 1 RO pump and valve states during flush modes Any time that a Flush is actually taking place while the system state is RUNNING the system will ignore the following er ror limits delivered product TDS high recovery low recovery high reject low membrane pressure drop pump feed pressure low Once the flush ends the error checking will resume If the inlet pressure switch ...

Страница 30: ...nually by a STORAGE TANK FULL er ror by a pretreatment lockout command or other states This is a low pressure flush Press or and then to change the value if necessary FLUSH DURATION 3 MINUTES 1 180 9 If standby mode is set to ON the screen displays the flush du ration setting Press or and then to change the value and then display the next setting FLUSH EVERY 3 HOURS 1 24 10 If standby mode is set ...

Страница 31: ...ng Press or and then to change the value and then return to the Flush Mode menu QUAL FLUSH MODE DISABLE Disable 18 The screen displays the Quality Flush Mode setting When the system is running the system sends all water to drain until a preset quality is reached at which time the water will flow to the product outlet This is a high pressure flush pump is on The quality flush mode is disabled and c...

Страница 32: ...of the circuit board Keep replacement boards in their special anti static bags until ready for use Mishandling of the circuit board will void the warranty 2 Use the Hole Drilling Template as a guide to drilling two holes to mount the remote monitor If drilling into wall board drill two 5 16 diameter holes and insert the plastic drywall anchors into the holes securing them with the two 10 screws pr...

Страница 33: ...tion of this manual to configure the main controller to use the modem in the remote Wireless Remote Setup Begin the wireless setup using the wireless remote device running jan 01 12 12 01P 1 From the default home screen press The screen displays the main menu 1 INFORMATION 2 SETUP 3 DIAGNOSTICS 2 Press to select 2 SETUP 1 RF SETUP 2 MODEM SETUP 3 Press to select 1 RF SETUP Wireless Remote Settings...

Страница 34: ...ES 5 ACCESSORIES 4 Press to select 5 ACCESSORIES The screen displays the ac cessories menu 1 WIRELESS REM 2 MODEM 3 FLOW METERS 4 SWITCH INPTS 5 Press to select 1 WIRELESS REM The screen displays the accessories menu REMOTE DISPLAY NOT INSTALLED 6 Press or and then to change the state to INSTALLED channel 1 7 Press or and then to select the channel number of the control valve The CHANNEL for the R...

Страница 35: ...ESTPHONELIN 3 USE DATA PORT 4 TEST APP 5 Press to select 1 TST WIRELESS The screen displays the wireless test screen wireless test 0 188 rssi 5 6 The screen displays the test number and total number of attempts and the re ceived signal strength indicator RSSI The system will continue to test the signal strength until you press any button to return to the diagnostics menu The signal strength indica...

Страница 36: ...connections have been made restore power 5 Connect the modem to the telephone line by plugging a standard RJ 11 phone extension cord into the modem board NOTE The GBE RO Controller is designed to plug into an analog telephone line standard residential phone line This includes phone lines connected to most residential VoIP voice over Internet phone sys tems and to residential DSL phone systems If y...

Страница 37: ...s of the remote housing back together using light finger pressure and insert the two screws Figure 14 Modem installed on back of remote board GBE RO Controller Modem Setup running jan 01 12 12 01P 1 From the default home screen press The screen displays the main menu 1 go to running 2 go to offline 3 information 4 setup 2 Press to scroll to 4 SETUP 3 Press to select the SETUP menu 2 LANGUAGE 3 pow...

Страница 38: ... then to specify the time zone of the RO Controller location with respect to Greenwich Mean Time GMT When using a modem the controller will occasionally access the Internet to synchronize the date and time In order to do this correctly the control must be told which time zone it is installed in The time zone is specified as so many hours ahead or behind GMT time The GMT offset for some common citi...

Страница 39: ...st Modem This menu attempts to send a test message The screen indicates whether or not this process is successful Sending a test message will also update the time and date on the Smart Controller to the correct time If the modem is installed on the main controller as opposed to installed in the remote control then this testing process will also check to see if there is an updated version of firmwa...

Страница 40: ...o select 2 MODEM SETUP The screen dis plays the modem settings Use these to set up the communication between the wireless remote and the Culligan servers GBE RO Controller Modem Settings on Remote Screen Display Range Changing the Setting TELEPHONE MODEM NOT INSTALLED Installed Not Installed The screen displays the installation status of the modem Press to change the state to installed if a teleph...

Страница 41: ...rn the valve all the way in a counter clockwise direction 2 Start the RO 3 When the pump turns on slowly close the waste and recirc valves clockwise 4 Try to close the waste valve until the flow rates to product and to drain are approximately even then begin to close the recirc valve to bring the membrane feed pressure within the range of 80 120 psi 5 Set the K Factor for both FM1 and FM2 at the v...

Страница 42: ...FLOW DISPLAYED is displayed on the GBE RO controller PFLOW ACTUAL Actual Product in gallons per minute 10 Verify that the displayed values on the GBE RO controller match the actual values 11 The measured calculated flow rates should be verified at the target flow rates If not repeat this procedure running jan 01 12 12 01P 1 From the default home screen press The screen displays the main menu 1 go ...

Страница 43: ...een displays the installation status of the flow meter Press to change the state to installed if a flow meter is in stalled in the RO system FM1 K FACTOR 80 0 0 9999 Press or and then to change the K Factor to the calculated value for the flow meter FM1 and or FM2 running jan 01 12 12 01P 6 Press to save the settings and return to the home screen ...

Страница 44: ...page 57 for this value NOTICE The Global RO Controller has a feature which records historical data The intial startup data is kept in the controllers memory It is still a good idea to record the values on a separate sheet of paper and keep the data near the unit in case of electrical problems 13 Choose GO TO OFFLINE from the main menu Connect the product tubing to the service plumbing 14 Test the ...

Страница 45: ... the pressure is ok then the pump starts and the display says RUNNING Figure 16 OFFLINE to RUNNING at the end of SV1 Delay time the unit checks the pressure switch input If the pressure is NOT ok then the unit turns off the SV1 output the pump output stays OFF and the displays says OFFLINE and PROBLEM FOUND display says STARTING then the SV1 output turns ON the pump output is OFF and the SV1 Delay...

Страница 46: ...how long the system should stay in starting mode before checking the pressure switch status and deciding whether or not to start the pump Auto restart In the event of a low pressure shutdown an auto restart attempt should be made Basically the system goes into starting mode again There can be a maximum of 5 restart attempts After the 5th successful restart the next low pressure shutdown should put...

Страница 47: ...V1 Delay 10 SECONDS 0 300 The number of seconds elapsed from the inlet solenoid valve SV 1 opening until the motor starts Press or and then to change PRETREAT SWITCH NORMALLY OPEN Normally Open Normally Closed Used with the inlet pressure switch Standard pressure switch is normally open Press or and then to change the state if necessary FLOAT SWITCHES NORMALLY OPEN Normally Open Normally Closed Us...

Страница 48: ...s the TDS settings TDS Probe Settings Screen Display Range Changing the Setting TDS PROBE NONE None Product Both For the M2 RO there is only one TDS probe so the correct set ting is PRODUCT Press or and then to change the state if necessary ACTUAL TDS OUT 0 PPM 0 6000 TDS1 0 200 TDS2 Disconnect the TDS probe from the RO plumbing and submerge it into a solution of known TDS Press or to enter the ac...

Страница 49: ...Status is selected on the display this relay is energized holding the normally closed contact open and when the GBE board has power AND there are no errors present the relay is energized Problem Found is not showing on the Home screen The relay is in the de energized state when the GBE is either powered OFF or when there is an error present on the GBE board LAMP 24VAC SUPPLY NO TERMINAL COM TERMIN...

Страница 50: ... product water produced after the relay is turned on Press or to enter the actual TDS value GROC Alarm Signal Output The GBE RO controller Alarm Signal Output is provided through three screw terminals located on the alarm relay board These terminals provide a pair of dry contacts rated at 30VDC x 10A One dry contact is open and one is closed at all times as defined in Table 3 below When GBE RO Con...

Страница 51: ...48 M2 5 3 45 02 99 90 3 75 5 400 0 51 M2 4 2 30 00 99 95 2 63 3 787 0 26 Table 4 Two pass RO arrays Two Pass RO Start Up Sequence When configured for two pass RO the master unit runs a start up sequence described as follows The SV1 on the GBE master opens The system waits for the amount of time set on the master as SV1 Delay If the pressure switch 1 shows that pressure is present then the GBE mast...

Страница 52: ...here is no pre treat ment lockout condition in effect The units will continue to switch over control at the top of each hour indefinitely For example the master RO pumps on even hours 12 00 to 1 00 2 00 to 3 00 4 00 to 5 00 etc and the slave RO pumps on odd hours 1 00 to 2 00 3 00 to 4 00 5 00 to 6 00 etc If at any time while in duplex alternating mode either Unit A or Unit B stops functioning or ...

Страница 53: ... 1 2 3 NOTE MAKE SURE TO COVER PINS 1 2 ON THE JUMPERS WHEN CONNECTING TWO UNITS TOGETHER JUMPER Figure 23 Wiring for two pass and alternating mode 81 7 9 6 7 81 7 9 6 7 81 7 81 7 35 75 7 6 67 0 21752 5 37 2 37 2 20081 7 21 Figure 24 RO duplex alternating plumbing ...

Страница 54: ...ating Press or and then to select the RO system configuration MUL UNIT RO ROLE MASTER Master Slave If you select Two Pass RO or Alternating press or and then to select MASTER if the selected RO will control the func tions of the entire RO system Select SLAVE if the selected RO will be controlled by the master RO Operating System Information for a Two Pass RO Once the units are set for TWO PASS RO ...

Страница 55: ...nstalled on both units P1 and P2 are the pressure sensors on the Master unit First Pass P3 and P4 are the pressure sensors on the Slave unit Second Pass PRES SW1 OPEN PRES SW2 CLOSE SW1 is the pressure switch on the Master unit First Pass SW2 is the pressure switch on the Slave unit Second Pass FEED QLTY IN BAD This is the status of the pretreat lockout input on the Slave unit Sec ond Pass If the ...

Страница 56: ...t was put into service ERROR 1 Water Press Low JAN 01 12 12 01P This screen displays the last one to five errors flagged by the unit If no errors are flagged the display reads NONE FWR202LT04 Feb 1 2013 S N 00003790 This screen shows the firmware version born on date and serial number for the Master unit NOTE Both units should have the SAME firmware version and born on date HISTORICAL DATA JAN 01 ...

Страница 57: ... mode This is the default SV3 mode Permeate Flush Solenoid valve SV3 is open whenever the RO system is in Permeate Flush mode TDS Target Target TDS The RO system keeps track of the average product water TDS whenever the RO system is operating mixing lower quality water with product water to meet the average product water TDS The average TDS measurements of the RO product water are taken once per s...

Страница 58: ...ODE TDS TARGET TDS Target Flush Modes Press or and then to select whether SV3 will be used to maintain a target TDS or used with quality flush mode TDS TARGET VALUE 100 PPM 0 500 If TDS Target is selected press or and then to specify the target TDS of the product water delivered by the RO system TDS TARGET TIME 5 MINUTES 5 60 Press or and then to specify the time allowed to open solenoid valve SV3...

Страница 59: ...the system Test the concentrate water for sulfite continue flushing until no sulfite is detected CAUTION As the concentrate flow is reduced the system pressure will increase Open the sys tem pressure control valve as required to prevent the system pressure from exceeding 150 psi 1553 kPa Excessive pressure will damage the system NOTICE Depending on the feed water quality it may be possible to oper...

Страница 60: ...e of electrical problems 11 Turn the power switch OFF Connect the product tubing to the service plumbing 12 Test the operation of the pressure switch by closing the inlet water supply valve The unit should shut off imme diately and the Low Pressure light should turn on CAUTION If the unit does not shut off turn the unit OFF immediately to prevent pump damage Disconnect electrical power source then...

Страница 61: ...n determine the temperature correction factor from Table 6 Example At a temperature of 55 F the factor is 1 54 Temp F Temp C Correction Factor Temp F Temp C Correction Factor 40 4 4 2 12 75 24 1 04 45 6 7 1 90 80 27 0 95 50 10 1 71 85 29 0 86 55 13 1 54 90 32 0 79 60 16 1 39 95 35 0 72 65 18 1 26 100 38 0 66 70 21 1 14 Table 6 Temperature Correction Factors 8 Multiply the result of step 6 by the t...

Страница 62: ...formation screen dis plays the TDS average in ppm This should be the average TDS out value over the last 10 cycles of TDS Target Time If the RO is offline not running the screen displays FM OR TDS DISABLE RECOVERY 0 0 PFLOW 0 00 GPM TDS OUT 169 0 0 00 0 999 Alternate information screen showing recovery rejection product flow and product TDS If the RO is offline not running the screen displays FM O...

Страница 63: ...OC board serial number HISTORICAL DATA JAN 01 REJ 97 REC 50 DP 77 PSI 100 1000 The GROC has a built in data logging feature which takes a snap shot at the start of each month The first time each month that the system has been in a RUNNING state for a continuous 10 minute block of time the system will save the current values of Totalized gallons since new Current recovery Current rejection Current ...

Страница 64: ...ncentrate flow too high C Check and adjust concentrate flow re place tubing on A D Product flow too high D Test modules 3 Unit running but poor quality less than 95 rejection A Low pump pressure A See 2 B Module failure B Replace modules Check product line over pressurization C Concentrate throttling valve open C Throttle valve down D Poor seal on endcap D Check o rings inside endcap Replace o rin...

Страница 65: ...ATURE HIGH The temperature is above specification level WATER TEMPERATURE LOW The temperature is below specifcation level HIGH TDS OUT The product TDS goes above the value set in MAX TDS OUT This indicates that the membranes may be getting fouled and are losing their rejection capability PUMP PRESSURE LOW The pressure to the first array of membranes falls below the value set for MAX FEED PRESS Thi...

Страница 66: ... setting change or that the membrane is fouling MAX PUMP TIME The pumping time has reached the specified limit NO REMOTE SIGNAL The system and the wireless remote lose contact An optional wireless remote must be installed to see this message NO DIAL TONE The wireless remote is not indicating a dialup connection An optional wireless re mote must be installed to see this message LOW BATTERY The batt...

Страница 67: ...factory and should not need to be changed even if the flow sensor is replaced Should it become necessary to recalibrate or reenter the K Factor you can use one of the two methods below An ex ample of this would be when replacing the circuit board Method A Method B This method involves resetting the K Factor to the factory setting Every unit shipped has a data sheet in the control ler which lists t...

Страница 68: ...een damaged or cannot be cleaned Refer to Figure 26 1 Turn off the system Allow pressure to be completely relieved Turn main feed line to RO off 2 Remove retaining clips from both ends of all vessels 3 Remove end caps from all vessels with the tubing remaining in place Note placement the caps to assure re installation in the same orientation 4 Remove the RO element from the housing Note orientatio...

Страница 69: ... housing to be tested 2 Choose GO TO RUNNING from the main menu 3 Measure the product flow and TDS from the test element 4 Choose GO TO OFFLINE from the main menu 5 Reinstall the tubing 6 Continue testing the elements as needed to determine which should be cleaned or replaced Cleaning Modules During the operation of any reverse osmosis system dissolved solids and particulate matter are concentrate...

Страница 70: ...mance of the elements was not due to a change in operating conditions it may be time to clean the elements In general clean the elements 1 When the product flow rate decreases by 10 or when the feed pressure must be increased by 10 to main tain the same product flow or 2 When the percent of rejection decreases below specification NOTICE Replace the prefilter cartridges if they are discolored by ir...

Страница 71: ...bottom of the tank must be higher than the pump on the RO unit to prevent cavita tion of the pump when solution is drawn from the tank 3 Tubing 1 2 O D to connect cleaning adapter ahead of Pre filter 4 A pH meter 5 A pre filter cartridge P N 00955004 Before proceeding record the NOW values in Table 7 on page 66 Prepare the Equipment for Cleaning 1 Choose GO TO OFFLINE from the main menu 2 Place th...

Страница 72: ...menu After approximately 5 gallons have been drawn from the solu tion tank Choose GO TO OFFLINE from the main menu 5 Allow elements to soak for 15 minutes Choose GO TO RUNNING from the main menu Draw another 5 gallons from the solution tank Choose GO TO OFFLINE from the main menu 6 Remove the end of concentrate tubing from the drain and place it in the solution tank 7 Choose GO TO RUNNING from the...

Страница 73: ...prepare a fresh batch of phosphoric acid and sodium hydroxide For more accurate testing use a Hach Model DE 2 detergent test kit or equivalent to ensure that the product water is less than 0 05 ppm detergent A plastic gallon jug filled with ice may be placed in the solution tank to cool the solution CAUTION The temperature of the chemical solution will rise as it is recirculated If the tempera tur...

Страница 74: ...essful contact the service department at Culligan International Company for suggestions on alternate cleaning chemicals If cleaning has been successful note which chemicals were effective Use the same chemical s when the unit is cleaned again 6 Replace the Pre filter cartridge 7 After cleaning and rinsing have been completed connect the product tubing to the service line Remove the jumper installe...

Страница 75: ... 7 352 8 7 81 7 7 6 6 72 21752 5 1 3 35 6685 1 725 36 35 6685 6 7 9 1 21752 9 9 69 62 12 9 9 7 6 7 6 352 2 1 725 6 2 6 1625 9 9 9 3 1 1 3 211 7 21 72 352 66 25 167580 17 6833 75 35 6685 5 8 725 86720 5 6833 6 69 36 3 7 6 6 72 21752 5 69 237 21 237 21 48 7 86 72 5 1 237 21 3 50 7 86 7 1 237 21 3 50 7 86 69 237 21 3 9 6 6 9 6 7 03 6 237 21 67 86 69 237 21 237 21 ...

Страница 76: ...ED and creates an electrical connection between A and B A B A B In a float switch that is NORMALLY OPEN there is no electrical connection between A and B when water level is below the float Hi Level Float Switch Lo Level Float Switch STORAGE TANK Pretreatment Lockout Connection a NORMALLY OPEN PTLO Switch is open normally but closes during softener regeneration PRETREATMENT SOFTENER INLET PRESSURE...

Страница 77: ...mponents and Water Connections 208 230V 60 Hz U S Global RO Controller 5 Pump Motor 4 Throttling Valve 12 Product Flow Meter Membrane Assemblies 9 Pump Pressure Gauge 44 Waste and Recirculation Valves 13 45 Prefilter Figure 28 M2 RO front view Left Side View Right Side View Figure 29 M2 RO side views ...

Страница 78: ...y 2 1 01021927 01021927 9 Membrane Array 3 1 01021928 01021928 01021928 9 Membrane Array 2 2 01021963 0102163 9 Membrane Array 3 2 01021962 12 Gate Valve 01021544 13 Filter 10 Big Blue 01018049 38 Flow Meter 3 4 NPT 01021259 44 Pressure Gauge 0 200 PSI 2 5 1 4 CBM 01022978 45 Cartride Filter 5 micron 10 BB 00403232 59 Harness Meter 44 L 01021896 Cord Motor Power M2 01022319 Product Flow Meter Pump...

Страница 79: ... NIPPLE 3 4X4 PVC SCH 80 PE 2 4 Nipple 3 4x2 PVC Sch 80 TOE 3 5 Nipple 3 4x2 1 2 PVC Sch 80 TOE 1 6 Tee 3 4 Socket PVC Sch 80 2 7 Bushing 3 4x1 4 TxT PVC Sch 80 1 8 Bushing 3 4x1 2 SxT PVC Sch 80 1 9 Elbow 3 4 SxS PVC Sch 80 3 10 Elbow 3 4 TxT PVC Sch 80 2 11 ADAPTER HOSE BARB 3 4 X 3 4 NPTE 2 12 Fitting Male Connector 1 2Tx1 2NPTE PI 1 13 01021543 Check Valve 1 14 Nipple 1 2xClose PVC Sch 80 TBE ...

Страница 80: ... 230V 60 Hz U S 1 1 3 5 4 1 5 Figure 33 M2 product piping assembly Item Part No Description Quantity 01021941 Piping Assembly Product 1 Tee Threaded 50 PVC Sch 80 NPT 2 3 Nipple 1 2xClose PVC Sch 80 TBE 1 4 Nipple 1 2x5 PVC Sch 80 TBE 1 5 Fitting Male Adapter J G PP011624W 1 2 2 ...

Страница 81: ...Part No Description Qty 01021940 Piping Assembly M2 Concentrate 1 01021539 Valve Needle 1 2 Brass 2 2 Fitting Male Adapterr 1 2Tx1 2NPTE PI 4 3 Fitting Stem Elbow 1 2Tx1 2Stem PI 2 4 Fitting Union Tee 1 2T PI 1 5 00901801 Tubing 1 2 PE Natural 6 Fitting Union Elbow 1 2T PI 1 5 5 5 5 NOTE Cut Tubing to 2 NOTE Cut Tubing to 2 5 NOTE Cut Tubing to 2 5 6 ...

Страница 82: ...Include 2 Figure 35 M2 membrane vessel Item Part No Description Per Vessel 1 01021540 Housing Filter Wave Cyber FRP 4 End Port 1 2 01024290 Membrane CSM 4 x40 1 3 01023073 End Plug Assembly 4 2 4 P1021848 O Ring Head Seal 4 20 pack 2 1 Housing comes with everthing except the membrane 4 Each vessel requires two 2 individual o rings NOT two 2 packages of o rings ...

Страница 83: ...21927 Filter Array 2 1 1 Mount Filter 2 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 2 3 Plug 1 2 Threaded PVC Sch 80 2 4 01021090 Pipe PEX 1 2 1 5 Fitting PEX Stem Elbow 1 2 2 6 Fitting Stem Elbow 1 2Tx1 2Stem PI 1 7 Bushing 3 4x1 2 TxT PVC Sch 80 3 8 Fitting PEX Male Connector 1 2 2 9 Fitting Male Connector 1 2Tx1 2NPTE PI 3 10 11 00901801 Tubing 1 2 PE Natural 12 Fitting Union Elbow 1 ...

Страница 84: ...No Description Qty 01021963 Filter Array 2 2 1 Mount Filter 2 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 2 3 Plug 1 2 Threaded PVC Sch 80 2 4 Fitting Stem Elbow 1 2Tx1 2 Stem PI 4 5 Bushing 3 4x1 2 TxT PVC Sch 80 4 6 Fitting Male Connector 1 2Tx1 2NPTE PI 6 7 00901801 Tubing 1 2 PE Natural 10 Fitting Union Elbow 1 2T PI 2 11 Fitting Union Tee 1 2T PI 1 12 01008007 Element RO 4 Dia x 40 ...

Страница 85: ... 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 3 3 Plug 1 2 Threaded PVC Sch 80 3 4 01021090 Pipe PEX 1 2 5 Fitting PEX Stem Elbow 1 2 4 6 Bushing 3 4x1 2 Txt PVC Sch 80 5 7 Fitting PEX Male Connector 1 2 4 8 Fitting Stem Elbow 1 2Tx1 2Stem PI 1 9 Fitting Male Connector 1 2Tx1 2NPTE PI 4 10 00901801 Tubing 1 2 PE Natural 11 Fitting Union Tee 1 2T PI 2 12 Fitting Union Elbow 1 2T PI 2 15 Adap...

Страница 86: ...cription Qty 01021962 Filter Array 3 2 1 Mount Filter 3 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 3 3 Plug 1 2 Threaded PVC Sch 80 3 4 Fitting Stem Elbow 1 2Tx1 2Stem PI 6 5 Bushing 3 4x1 2 Txt PVC Sch 80 6 6 Fitting Male Connector 1 2Tx1 2NPTE PI 9 7 00901801 Tubing 1 2 PE Natural 8 Fitting Union Tee 1 2T PI 2 9 Fitting Union Elbow 1 2T PI 2 12 01008007 Element RO 4 Dia x 40 Filmtec T...

Страница 87: ...M2 RO Parts Diagrams and Lists 83 Cat No 01023095 Controller Sub Assembly 208 230V 60 Hz U S 9 10 1 Figure 40 M2 Controller front panel 2 11 Figure 41 M2 Controller main and auxiliary boards ...

Страница 88: ...84 Culligan Series M2 Reverse Osmosis 84 Cat No 01023095 Figure 42 M2 Controller cords and miscellaneous parts 3 14 Figure 43 M2 Controller relay board ...

Страница 89: ...eries Matrix Solutions 1 01024191 Enclosure GBE Small 1 2 01021527 Circuit Board Main GBE Commercial RO 1 3 01023100 GBE 115 230V RELAY BOARD 1 01022953 CABLE 22 AWG 2 CONDUCTOR W MTA100 CONN 3 7 01020719 Cover Plate GBE Enclosure 1 9 01020498 Membrane Keypad Oval w Connector 1 10 01020493 Decal GBE Face Plate 1 11 01020308 Circuit Board Aux I O GBE 1 ...

Страница 90: ...igure 44 Remote display assembly Remote Display Assembly Parts List 208 230V 60 Hz U S Item No Part No Description 01021586 Remote Display Assembly RO 915 MHz 1 01025686 Circuit Board Remote English Replacement 2 01020750 Circuit Board RF GBE 915 MHz 3 01020611 Power Supply Switching Wall Mount 100VAC 240VAC ...

Страница 91: ...Flow gpm L min 2 34 8 84 3 39 12 81 4 38 16 56 5 25 19 87 5 83 22 08 Concentrate Flow gpm L min 2 34 8 84 2 26 8 53 2 91 11 04 1 75 6 63 1 94 7 36 Recovery Design 50 60 60 75 75 Minimum 40 50 50 60 60 Maximum Module Feed Pressure psig kPa 160 1103 Nominal Module Feed Pressure psig kPa 140 965 Maximum Product Pressure psig kPa 40 276 Operating Temperature F C 40 100 4 38 Inlet Pressure Minimum dyna...

Страница 92: ...ter Connections 220V 50 Hz International Global RO Controller 5 Pump Motor 4 Throttling Valve 12 Product Flow Meter Membrane Assemblies 9 Pump Pressure Gauge 44 Waste and Recirculation Valves 13 45 Prefilter Figure 45 M2 RO front view Left Side View Right Side View Figure 46 M2 RO side views ...

Страница 93: ...1927 9 Membrane Array 3 1 01021928 01021928 01021928 9 Membrane Array 2 2 01021963 01021963 9 Membrane Array 3 2 01021962 12 Gate Valve 01021544 13 Filter 10 Big Blue 01018049 Flow Meter 1 2 NPT 01021033 38 Flow Meter 3 4 NPT 01021259 44 Pressure Gauge 0 200 PSI 2 1 2 1 4 CBM 01022978 45 Cartridge Filter 5 micron 10 BB 00403232 59 Harness Meter 38 L 01023700 Cord Motor Power M2 01022319 Product Fl...

Страница 94: ...0 PE 1 3 NIPPLE 3 4X3 PVC SCH 80 PE 2 4 Nipple 3 4x2 1 2 PVC Sch 80 TOE 3 5 Nipple 3 4x2 PVC Sch 80 TOE 1 6 Tee 3 4 Socket PVC Sch 80 2 7 Bushing 3 4x1 4 SxT PVC Sch 80 1 8 Bushing 3 4x1 2 SxT PVC Sch 80 1 9 Elbow 3 4 SxS PVC Sch 80 3 10 Elbow 3 4 TxT PVC Sch 80 2 11 ADAPTER HOSE BARB 3 4 X 3 4 NPTE 2 12 Fitting Male Adapter 1 2Tx1 2NPTE PI 1 13 01021543 Check Valve 1 14 Nipple 1 2xClose PVC Sch 8...

Страница 95: ...ternational 1 1 3 5 4 1 5 Figure 50 M2 product piping assembly Item Part No Description Quantity 01021941 Piping Assembly Product 1 Tee Threaded 50 PVC Sch 80 NPT 2 3 Nipple 1 2xClose PVC Sch 80 TBE 1 4 Nipple 1 2x5 PVC Sch 80 TBE 1 5 Fitting Male Adapter J G PP011624W 1 2 2 ...

Страница 96: ...y Item Part No Description Qty 01021940 Piping Assembly M2 Concentrate 1 01021539 Valve Needle 1 2 Brass 2 2 Fitting Male Adapter 1 2Tx1 2NPTE PI 4 3 Fitting Stem Elbow 1 2Tx1 2Stem PI 2 4 Fitting Union Tee 1 2T PI 1 5 00901801 Tubing 1 2 PE Natural 6 Fitting Union Elbow 1 2T PI 1 5 5 5 5 NOTE Cut Tubing to 2 NOTE Cut Tubing to 2 5 NOTE Cut Tubing to 2 5 6 ...

Страница 97: ...de 2 Figure 52 M2 membrane vessel Item Part No Description Per Vessel 1 01021540 Housing Filter Wave Cyber FRP 4 End Port 1 2 01024290 Membrane CSM 4 x40 1 3 01023073 End Plug Assembly 4 2 4 P1021848 O Ring Head Seal 4 20 pack 2 1 Housing comes with everything except the membrane 4 Each vessel requires two 2 individual o rings NOT two 2 packages of o rings ...

Страница 98: ...Qty 01021927 Filter Array 2 1 1 Mount Filter 2 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 2 3 Plug 1 2 Threaded PVC Sch 80 2 4 01021090 Pipe PEX 1 2 1 5 Fitting PEX Stem Elbow 1 2 2 6 Fitting Stem Elbow 1 2Tx1 2Stem PI 1 7 Bushing 3 4x1 2 TxT PVC Sch 80 3 8 Fitting PEX Male Connector 1 2 2 9 Fitting Male Connector 1 2Tx1 2NPTE PI 3 10 11 00901801 Tubing 1 2 PE Natural 12 Fitting Union E...

Страница 99: ...escription Qty 01021963 Filter Array 2 2 1 Mount Filter 2 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 2 3 Plug 1 2 Threaded PVC Sch 80 2 4 Fitting Stem Elbow 1 2Tx1 2 Stem PI 4 5 Bushing 3 4x1 2 TxT PVC Sch 80 4 6 Fitting Male Connector 1 2Tx1 2NPTE PI 6 7 00901801 Tubing 1 2 PE Natural 10 Fitting Union Elbow 1 2T PI 2 11 Fitting Union Tee 1 2T PI 1 12 01008007 Element RO 4 Dia x 40 Film...

Страница 100: ...er 3 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 3 3 Plug 1 2 Threaded PVC Sch 80 3 4 01021090 Pipe PEX 1 2 5 Fitting PEX Stem Elbow 1 2 4 6 Bushing 3 4x1 2 Txt PVC Sch 80 5 7 Fitting PEX Male Connector 1 2 4 8 Fitting Stem Elbow 1 2Tx1 2Stem PI 1 9 Fitting Male Connector 1 2Tx1 2NPTE PI 4 10 00901801 Tubing 1 2 PE Natural 11 Fitting Union Tee 1 2T PI 2 12 Fitting Union Elbow 1 2T PI 2 1...

Страница 101: ...ription Qty 01021962 Filter Array 3 2 1 Mount Filter 3 2 2 01021540 Housing Filter Wave Cyber FRP 4 End Port 3 3 Plug 1 2 Threaded PVC Sch 80 3 4 Fitting Stem Elbow 1 2Tx1 2Stem PI 6 5 Bushing 3 4x1 2 Txt PVC Sch 80 6 6 Fitting Male Connector 1 2Tx1 2NPTE PI 9 7 00901801 Tubing 1 2 PE Natural 8 Fitting Union Tee 1 2T PI 2 9 Fitting Union Elbow 1 2T PI 2 12 01008007 Element RO 4 Dia x 40 Filmtec TW...

Страница 102: ...8 Culligan Series M2 Reverse Osmosis 98 Cat No 01023095 Controller Sub Assembly 220V 50 Hz International 9 10 1 Figure 57 M2 Controller front panel 2 11 Figure 58 M2 Controller main and auxiliary boards ...

Страница 103: ...Series M2 International 99 Cat No 01023095 Figure 59 M2 Controller cords and miscellaneous parts 3 14 Figure 60 M2 Controller relay board ...

Страница 104: ...ler M2 Series Matrix Solutions 1 01024191 Enclosure GBE Small 1 2 01021527 Circuit Board Main GBE Commercial RO 1 3 01023100 GBE 115 230V RELAY BOARD 1 01022953 CABLE 22 AWG 2 CONDUCTOR W MTA100 CONN 3 7 01020719 Cover Plate GBE Enclosure 1 9 01020498 Membrane Keypad Oval w Connector 1 10 01020493 Decal GBE Face Plate 1 11 01020308 Circuit Board Aux I O GBE 1 ...

Страница 105: ... English D1025679 Remote Display Assembly RO 869 MHz French D1025680 Remote Display Assembly RO 869 MHz Italian D1025681 Remote Display Assembly RO 869 MHz Spanish 1 01025686 Circuit Board Remote English Replacement 1 01025683 Circuit Board Remote French Replacement 1 01025684 Circuit Board Remote Italian Replacement 1 01025685 Circuit Board Remote Spanish Replacement 2 01020751 Circuit Board RF G...

Страница 106: ...ressure causes a flow through the semi permeable membrane into the dilute solution The semi permeable membrane acts as a barrier to ions and does not allow them to pass through into the dilute solution When applied to water this means that the product water has a reduced total dissolved solids content as a result of the passage of water molecules through the membrane while the mineral ions are rej...

Страница 107: ...and Product Flow PFLOW on the Information screen The Recovery is also displayed on an Information screen Use the following equation to calculate percent recovery Product Water Flow Rate PFLOW Feed Water Flow Rate FFLOW x 100 Recovery CAUTION An understanding of rejection recovery percentages and temperature compensation is essential for monitoring and evaluating the performance or condition of the...

Страница 108: ...104 Culligan Series M2 Reverse Osmosis 104 Cat No 01023095 Appendix C GBE RO Controller Menu Structure FWR LT04 MON DD YEAR ...

Страница 109: ...QX FKDUW 5525 0 76 67 57 83 67 57 83 02 2 86 85 7 21 0 187 6 21 67 1 02 2 86 85 7 21 0 187 6 21 67 1 86 9 5 2856 7 0 75 02 2 86 85 7 21 0 187 6 21 86 9 5 2856 7 0 75 5 2 75 02 2 86 85 7 21 0 187 6 21 86 9 5 216 48 86 02 2 86 85 7 21 0 187 6 21 7 6 9 2 75 5 48 86 3 50 86 2 86 85 7 21 0 187 6 21 3 50 86 0 35 66 0 1 5 7 0 5 29 5 0 1 5 29 5 0 1 7 03 0 1 1 7 03 0 35 66 0 1 35 66 0 7 6 287 0 38037 0 0 1...

Страница 110: ... 7 1250 23 1 69 HOD 6 21 6 35 75 7 6 7 1250 23 1 2 7 6 7 6 1250 23 1 6 L HOD 0 187 6 35 66 8 6 3 167 3 3 3 167 35 66 8 6 6 3 6 3 3 2 6 7 36 3 725 P9ROWV 36 3 6 3 2 6 7 36 3 725 P9ROWV 36 3 7 6 7 6 352 121 78 7 6 287 330 352 8 7 7 03 2 6 7 7 03 203 9 8 78 7 6 287 330 7 03 2 6 7 7 03 203 9 8 78 7 6 1 330 27 5 02 5 02 5525 67 786 2 75 5 DOV 38 6 287387 08 7 81 7 52 08 7 81 7 52 6 1 7 2 3 66 52 2U 7 5...

Страница 111: ...GBE RO Controller Menu Structure 107 Cat No 01023095 FWR LT04 MON DD YEAR ...

Страница 112: ...0202 00000 00000 00000 000 000 000 1023111027 Where the values for the fields A thru J are as follows A current membrane feed flow rate in gallons per minute 9 3 means 9 3 gpm B current flow rate in gallons per minute C Current Operational Status 1 running 2 standby 3 offline 4 error D Current recovery percentage 050 means 50 recovery E Current reject percentage 096 means 96 rejection F Storage Ta...

Страница 113: ...Once your cables are set up you can test your connection using the Windows Hyperterminal program This program is generally found under Start All Programs Accessories Communications Hyperterminal Name the New Connection 1 When you open Hyperterminal you will be prompted to create a name for the connection Enter any name 2 Click on an icon that represents your connection 3 Click on the OK button Set...

Страница 114: ...s to select the SETUP menu 3 poweron mode 4 FLUSH MODES 5 ACCESSORIES 6 DIAGNOSTICS 4 Press to select 6 DIAGNOSTICS The screen displays the diagnostics menu 1 TST WIRELESS 2 TESTPHONELIN 3 USE DATA PORT 4 TEST APP 5 Press to select 3 USE DATA PORT The screen displays the data re port status screen MINI REPORT Sending 6 Press to to send the mini report MINI REPORT Sent 7 The GBE RO controller displ...

Страница 115: ...w limit 0 NORM flow std pressure limit 120 Startup flush OFF Standby flush OFF Time trigger flush OFF Flow trigger flush OFF Quality flush ON 3 10 Permeate flush OFF TDS probe both Historical Data Month JAN Year 2012 Rejection 0 Recovery 0 0 PI PO 0 NFlow 0 0 Total Water 0 Product PPM 0 Figure 65 Data report from GBE RO Controller If you do not see the report check your settings and make sure the ...

Страница 116: ...s out side the United States RUNNING JAN 01 12 12 01P The home screen displays the RUNNING or OFFLINE status of the RO system Install Modem 1 GOTO RUNNING 2 GOTO OFFLINE 3 INFORMATION 4 SETUP Press to scroll to 4 SETUP and press for setup menu 2 LANGUAGE 3 POWERON MODE 4 FLUSH MODES 5 ACCESSORIES Select 5 ACCESSORIES 1 WIRELESS REM 2 MODEM 3 FLOW METERS 4 SWITCH INPUTS Select 2 MODEM TELEPHONE MOD...

Страница 117: ...US INCH Select METRIC for units out side the United States RUNNING JAN 01 12 12 01P The home screen displays the RUNNING or OFFLINE status of the RO system Set Up Flush Modes 1 GOTO RUNNING 2 GOTO OFFLINE 3 INFORMATION 4 SETUP Press to scroll to 4 SETUP and press for setup menu 1 TIME DATE 2 LANGUAGE 3 POWERON MODE 4 FLUSH MODES Select 4 FLUSH MODES 2 STANDBY 3 TIME TRIGGER 4 FLOW TRIGGER 5 GUAL F...

Страница 118: ...NG or OFFLINE status of the RO system Set Up GROC Remote Communication 1 WIRELESS REM 2 MODEM 3 FLOW METERS 4 SWITCH INPUTS From the main menu select 4 SETUP 5 ACCESSO RIES 1 WIRELESS REM WIRELESS REM NOT INSTALLED Change the setting to INSTALLED CHANNEL 1 Select the channel to com municate between the remote and the RO controller RF FREQUENCY 915MHz Select the radio frequency 915MHz for North Ame...

Страница 119: ... System Status at Startup POWERON MODE OFFLINE Select the system status at startup offline or running You can change status after setup Set Up Units of Measure Initialize System SYSTEM UNITS US INCH Select METRIC for units out side the United States RUNNING JAN 01 12 12 01P The home screen displays the RUNNING or OFFLINE status of the RO system Set Up Flush Modes 1 GOTO RUNNING 2 GOTO OFFLINE 3 IN...

Страница 120: ...uage English French Italian Spanish Time and Date Month Day Year Clock Type 12 Hr 24 Hr Hour Minutes Daylight Saving Yes No Power On Mode Power On Mode Running Standby System Units System Units US Inch Metric Flush Modes Startup Mode Off On Flush Duration Standby Mode Off On Flush Duration Flush Every Time Trigger Off On Flush Duration Flush Every Flow Trigger Off On Flush Duration Flush Every Qua...

Страница 121: ...able styles 109 Data GBE Historical 2 Data Input Program 15 Data Port Output 108 Data Stream Available 4 Date and Time Setting Up 17 Date Settings 21 Date Set Up 21 112 113 114 115 Default Menu 19 Diagnostics 63 Direct Feed 11 DOWN ARROW button 16 duplex alternating plumbing RO 49 Duplex Alternating RO Mode 48 E Electrical Connections 108 Electrical Installation 12 Error Codes 61 Error Flags E Mai...

Страница 122: ...nternational 88 Materials Required 7 MAX PUMP TIME 62 Membrane Assembly M2 2 and M2 4 208 230V 60 Hz U S 79 Membrane Assembly M2 2 and M2 4 220V 50 Hz Interna tional 94 Membrane Assembly M2 3 M2 5 and M2 6 208 230V 60 Hz U S 81 Membrane Assembly M2 3 M2 5 and M2 6 220V 50 Hz International 96 Membrane Assembly M2 4 and M2 5 208 230V 60 Hz U S 80 Membrane Assembly M2 4 and M2 5 220V 50 Hz Interna ti...

Страница 123: ...reless 29 Remote Setup Wireless 29 Remote Wireless 21 28 114 Replacement Membrane 64 Replacing the Prefilter Cartridge 64 Repressurization System 21 Rerun First Time Setup 19 Reverse Osmosis 102 Reverse Osmosis System Report from GBE RO Controller 108 RF board 29 RF Board 21 RO Installation 7 RO Module Tubing 8 RS 232 Outputs Available 4 RS 485 Outputs Available 4 Running Go To 20 S Select Languag...

Страница 124: ...est App 63 Testing Modules 65 Test Message from the GBE RO Controller Send a 110 Test Modem 35 Test Phone Line 63 Test the Data Port 109 Test Wireless Remote 63 Timeout Programming Mode 15 Time Settings 21 Time Set Up 21 112 113 114 115 Time Trigger Flush 24 Troubleshooting 60 Tubing RO Module 8 Two Pass RO 47 Two pass RO arrays 47 Two Pass RO Information Set tings for a 51 Two Pass RO Operating S...

Отзывы: