Culligan® Series M2 Reverse Osmosis
58
Cat. No. 01023095
System Operating Information
At any time, you can view the system operation information. The information includes settings and performance data.
1)GO TO RUNNING
2)GO TO OFFLINE
>3)INFORMATION
4)SETUP
1. Press
to select 3)INFORMATION.
Information Settings
NOTE When you display any Information screen, it will stay on the display until changed by the operator.
Screen Display
Range
Procedure
FFLOW 0.00 PGM
DFLOW 0.00 GPM
PFLOW 0.00 GPM
RECOVERY 0.0 %
0.00–??
The screen displays Feed Flow, Reject Flow(waste), Product Flow,
and Recovery. Flow Meters must be installed for this screen to dis-
play values.
TDS PPM
TDS IN = 1075
TDS OUT = 192
% REJ = 82
0.00–??
G2/G3 only: this screen shows the TDS of the incoming and prod-
uct water as well as the percent rejected. The TDS sensors must
be installed for this screen to display values.
If the RO is offline/not running, the screen displays FM OR TDS
DISABLE.
TDS AVERAGE
0
PPM
0–999
When SV3 is selected, the RO controller information screen dis-
plays the TDS average in ppm. This should be the average TDS-
out value over the last 10 cycles of “TDS Target Time.”
If the RO is offline/not running, the screen displays FM OR TDS
DISABLE.
RECOVERY 0.0%
PFLOW 0.00 GPM
TDS OUT = 169
0–??
0.00–??
0–999
Alternate information screen showing recovery, rejection, product
flow and product TDS.
If the RO is offline/not running, the screen displays FM OR TDS
DISABLE.
ACTUAL NFLOW:
0.00
GPM
0.00–??
This is the normalized product flow (flow at 77°F)
NOTE: This value is displayed only if the Min NFlow Error limit has
been set at a value greater than zero.
P IN 122 PSI
P OUT 124 PSI
dP -2 PSI
Incoming (G2 Plus and G3 only) pressure and waste pressure are
shown and the pressure differential (dP) is calculated. The screen
displays DISABLE if no pressure gauges are connected.
If the RO is offline/not running, the screen displays PRESS GAUG-
ES DISABLE.
Actual Temp:
91 F
The screen displays the temperature of the product water.
If TDS probe is not installed, the screen displays Actual Temp:
DISABLE
PS1 = OPEN
PTLO = OPEN
FS HI = OPEN
FS LO = OPEN
Indicates whether the pressure switch, pretreatment lockout, high
float switch or low float switch is open or closed (if installed).