Accessories
53
Cat. No. 01021713
Multiple Unit ROs
The GBE RO controller supports two multi-unit modes: Two Pass and Alternating.
When in two-pass or alternating mode, the system is configured to support two GBE RO controllers that are connected
trolling the operations of the other unit, also known as the slave. The slave unit performs as a sensing device.
Two-Pass RO
When in Two-Pass RO mode, the primary unit, identified as the master, issues commands to control the secondary unit,
identified as the slave.
FFLOW
IFLOW
PFLOW
Figure 31.
Two-pass RO process.
Two-Pass RO Start Up Sequence
When configured for two-pass RO, the master unit runs a start up sequence described as follows:
• The SV1 on the GBE master opens
• The system waits for the amount of time set on the master as “SV1 Delay”
• If the pressure-switch-1 shows that pressure is present, then the GBE master turns on the pump for the first unit.
• The system waits for the amount of seconds set on the master as the “PASS 2 DELAY”.
• If the pressure-switch-2 shows that pressure is present at pressure-switch-2 then the master sends an operation
command to the slave unit that turns on the second pass pump.
The master will turn off the slave’s motor output any time it detects that one of the inlet pressure switches is off for more
than the specified “PS SW DELAY”. After the slave unit pump turns off, the master will wait three (3) seconds and then
turn off the master pump. The units follow the same procedure if operating conditions trigger the PTLO or the Tank Full
switches.
G1 Series Two-Pass Pairings
NOTE The RO G1 Series Two-Pass requires that the unit have the firmware version FWR202LT04 with a born-
on-date no earlier than FEB 01 2013.
For hardware, plumbing, and wiring, order the following:
Required Kit Part Numbers
Two-Pass Offerings
Feed TDS>500
Feed TDS<500
G1 2L(master), 2S(slave)
01025957
01025959
G1 3L(master), 3S(slave)
01025957
01025959
G1 4L(master), 4S(slave)
01025957
01025959
G1 2F(master), 3L(slave)
01025957
01026007
Содержание G1 Series
Страница 80: ...76 Culligan Series G1 Reverse Osmosis 76 Cat No 01021713 GBE RO Controller Menu Structure FWR LT04 MON DD YEAR ...
Страница 81: ...GBE RO Controller Menu Structure 77 Cat No 01021713 ...
Страница 83: ...GBE RO Controller Menu Structure 79 Cat No 01021713 FWR LT04 MON DD YEAR ...
Страница 96: ...92 Culligan Series G1 Reverse Osmosis 92 Cat No 01021713 G1 1F Sub Assembly Figure 48 G1 1F sub assembly ...
Страница 98: ...94 Culligan Series G1 Reverse Osmosis 94 Cat No 01021713 G1 2F Sub Assembly Figure 49 G1 2F sub assembly ...
Страница 142: ......