32
Culligan® Series G1 Reverse Osmosis
32
Cat. No. 01021713
Setup
After completing the first time setup for the RO, you must also complete the system setup for flush modes, accessories,
and error limits before completing the initial startup.
Flow Meter K-Factor setting is required during setup. All other RO settings are optional depending on the accessories
installed. The RO controller does not require any specific setup to run unless accessories are installed or will be installed.
RO accessories include:
Accessory
Global RO Controller (GROC) Setting
Flush Valves
Setup—>Flush Modes
Flow Meters
Setup—>Accessories—>Flow Meters
Modem
Setup—>Accessories—>Modem
Wireless Remote, RF Board
Setup—>Accessories—>Wireless Rem—>Channel #
Level Controls
Setup—>Accessories—>Switch Inputs
Repressurization System
Setup—>Accessories—>Switch Inputs
Pretreatment Lockout
Setup—>Accessories—>Switch Inputs
Pressure Transducers (G2, G3 only)
Setup—>Accessories—>Press Gauges
System Setup
Set Up Time/Date
If the unit loses time for some reason, you can use this setting to reset the correct date and time. Please note that if you
have a modem installed and connected to the phone line, the unit will check for the correct time each time it calls in.
RUNNING
JAN-01-12 12:01P
1. From the default home screen, press
. The screen displays the main menu.
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
2. Press
to scroll to 4) SETUP.
3. Press
to select the SETUP menu.
>1) TIME/DATE
2) LANGUAGE
3) POWERON MODE
4) FLUSH MODES
4. Set Time/Date is the first menu item, so press
to select 1) SET TIME/DATE.
The screen displays the first setting that can be changed.
Time/Date Settings
Screen Display
Range
Procedure
SET
MONTH
JAN
Jan–Dec
1. The screen displays the month setting. Press
or
and then
to change the value and see the next setting.
SET
DAY
1
1–31
2. The screen displays the day setting. Press
or
and
then
to change the value and see the next setting.
Содержание G1 Series
Страница 80: ...76 Culligan Series G1 Reverse Osmosis 76 Cat No 01021713 GBE RO Controller Menu Structure FWR LT04 MON DD YEAR ...
Страница 81: ...GBE RO Controller Menu Structure 77 Cat No 01021713 ...
Страница 83: ...GBE RO Controller Menu Structure 79 Cat No 01021713 FWR LT04 MON DD YEAR ...
Страница 96: ...92 Culligan Series G1 Reverse Osmosis 92 Cat No 01021713 G1 1F Sub Assembly Figure 48 G1 1F sub assembly ...
Страница 98: ...94 Culligan Series G1 Reverse Osmosis 94 Cat No 01021713 G1 2F Sub Assembly Figure 49 G1 2F sub assembly ...
Страница 142: ......