![CTC Union EcoZenith I 550 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/ctc-union/ecozenith-i-550/ecozenith-i-550_installation-and-maintenance-manual_2693653064.webp)
For the property owner
64
CTC EcoZenith
I
550
Def Pool
Pool
Yes
Sensor 88
Active
Pool pump 39
Active
Pool pump 41
Active
Define Pool Menu
(Installer/Define application/Def Pool)
Pool
On this menu line the presence of a pool is defined. The factory setting is “No”.
When the setting is “Yes”, the menu lines are shown underneath.
These are turned off at the setting “No”.
Sensor 88
Indication that sensor (88) is activated. This sensor measures the temperature
in the pool and controls the start and stop conditions for pool charging.
Pool pump 39
Indication that circulating pump (39) is activated. This pump charges heated pool
water between the pool and heat exchanger (19).
Pool pump 41
Indication that circulating pump (41) is activated. This pump charges radiator
water from CTC EcoZenith
I
550 to the heat exchanger (19).
!
Pool control presumes circuit
board expansion (option).
Function test
Radiator system
Heat pump 1
Heat pump 2
Heat pump 3
Valves
Elec. heater
Solar Energy
Wood Boiler
Ext Boiler
Ext storage tank
Hot water
Pool
Function Test Menu
(Installer/Function test)
In the “Function test” menu the installation engineer can test the connection
and function of separate components in the heating system. When this menu
is activated, all functions in the CTC EcoZenith
I
550 are stopped. Only safety
functions are still activated. Return to normal operation occurs after 8 minutes
of inactivity.
Radiator system
In the Radiator System menu, radiator pumps and mixing valves are function tested.
Heat pump 1 (2, 3)
Compressors, circulating pumps and fans can be function tested separately under
these menu lines.
Valves
In this menu the 3-way valves are function tested for the heat pump operation.
Elec. heater
Here the immersion heaters are function tested.
Solar Energy
Circulating pumps and valves for the solar panels can be tested here.
Wood Boiler
Function test of charge pump flue gas (40).
Ext Boiler
The boiler for additional heating and the circulating pump can be turned on or off
in this menu.