43
For the property owner
CTC EcoZenith
I
550
Installer
Settings
Define application
Service
Installer Menu
(you access the menu directly from the main menu)
This menu contains three submenus. “Settings” and “Define system” are
used by the installation engineer and the user, and the “Service” menu
is used for fault tracing.
Settings
Select this menu to make your settings according to your own requirements.
Define application
This menu is used to tell the CTC EcoZenith
I
550 which components and subsystems
your heating system consists of. This information is used to control, check and meet
the heat and DHW needs of your house in the best and most economical way.
Furthermore, the CTC EcoZenith
I
550 sorts and hides menus which are not defined.
What is not defined is not shown.
Service
This menu is used by service personnel for fault tracing and diagnostics.
The menu also contains a coded section with alarm limits, intended for the
manufacturer’s settings only.
Settings
Language
English
Radiator system 1
Radiator system 2
Radiator system 3
Heat pump 1
Heat pump 2
Heat pump 3
Elec. heater
Upper Tank
Lower Tank
Solar Energy
Wood Boiler
Ext Boiler
Ext storage tank
Pool
Remote control
NS
Holiday
Off
Save my settings.
Retrieve my settings.
Load factory setting
Settings Menu
(Installer/Settings)
In the “Settings” menu the installation engineer and user perform settings
as needed and desired.
Language
English
Setting of Language.
Radiator system 1 (2, 3)
In this menu you make settings for defined radiator systems. Max and min
primary flow, summer mode (heat Off), curve slope and adjustment as well
as night reduction levels can be set.
Heat pump 1 (2, 3)
Here you make settings for defined heat pumps: settings for the compressor,
min outside temperature, prioritizations between heat pumps, rate and settings
for circulating pumps.
Elec. heater
Here you make settings which have to do with the immersion heaters of the CTC
EcoZenith
I
550. Among other things you can set permissible power, temperatures
in the lower part of the tank if the heat pumps should not be in operation, delay of
the mixing valve, main fuse etc.