Define Radiator System 1 Menu
(Installer/Define application/Def Radiator System 1)
Radiator system 1
Radiator System 1 is factory set to “Yes”. When the setting is “Yes”, the menu lines
are shown underneath. These are turned off if the setting is “No”.
Room sensor 1
Here you select if room sensor 1 is included in the operation.
4-way valve 59
Indication that 4-way valve (59), the bivalent mixing valve, is activated.
Rad pump 36
Indication that radiator pump (36) is activated.
Sensor 79
Indication that sensor (79) is activated. This is the primary flow sensor which
reads the temperature out to the radiator system 1.
Sensor 81
Indication that sensor (81) is activated. This is the return flow sensor which reads
the temperature back to the CTC EcoZenith
I
550.
Sensor 84
Indication that sensor (84), room sensor 1, is activated.
Def Radiator system 1
Radiator system 1
Yes
Room sensor 1
No
4-valve 59
Active
Rad pump 36
Active
Sensor 79
Active
Sensor 81
Active
Sensor 84
Active
Define Radiator System 2 Menu
(Installer/Define application/Def Radiator system 2)
Radiator system 2
Radiator system 2 is factory set to “No”. When the setting is “Yes”, the menu lines
are shown underneath. These are turned off at the setting “No”.
Room sensor 2
Here you select if room sensor 2 is included in the operation.
3-way valve 60
Indication that 3-way valve (60), the mixing valve for radiator system 2, is activated.
Rad pump 37
Indication that radiator pump (37) is activated.
Sensor 80
Indication that sensor (80) is activated. This is the primary flow sensor which
reads the temperature out to the radiator system 2.
Sensor 81
Indication that sensor (81) is activated. This is the return flow sensor which reads
the temperature back to the CTC EcoZenith
I
550.
Sensor 86
Indication that sensor (86), room sensor 2, is activated.
Def Radiator system 2
Radiator system 2
Yes
Room sensor 2
No
3-valve 60
Active
Rad pump 37
Active
Sensor 80
Active
Sensor 81
Active
Sensor 86
Active