Define Heat Pump 2 Menu
(Installer/Define application/Def Heat pump 2)
Heat pump 06
Here you select if heat pump 2 is included in the operation. The factory setting is
“No”. When the setting is “Yes”, the menu lines are shown underneath. These are
turned off at the setting “No”. Note that the setting locally in heat pump 2 (06)
should be “A2”. Thus, this setting is made in the heat pump’s own control.
Type
The type of heat pump is selected here. EcoPart or EcoAir.
Charge pump 32
Here you set the type of charge pump. “0-10V” is for a speed-controlled circulating
pump and “relay” for a pump with fixed speed setting.
Def Heat pump 2
Heat pump 06
Yes
Type
EcoAir
Charge pump 32
0-10V
Define Heat Pump 3 Menu
(Installer/Define application/Def Heat pump 3)
Heat pump 07
Here you select if Heat pump 3 is included in the operation. The factory setting
is “No”. When the setting is “Yes”, the menu lines are shown underneath. These are
turned off at the setting “No”.
Note that the setting locally in heat pump 3 (07) should be “A3”. Thus, this setting
is made in the heat pump’s own control.
Type
The type of heat pump is selected here. EcoPart or EcoAir.
Charge pump 33
Here you set the type of charge pump. “0-10V” is for a speed-controlled circulating
pump and “relay” for a pump with fixed speed setting.
Def Heat pump 3
Heat pump 07
Yes
Type
EcoAir
Charge pump 33
0-10V
Define Electric Heaters Menu
(Installer/Define application/Def Elec. heaters)
Upper heater 14
Here you select if the upper immersion heater (14) should be included in
the operation.
The factory setting is “Yes”.
Upper heater 15
Here you select if the upper immersion heater (15) should be included in
the operation.
The factory setting is “No”. This immersion heater is optional.
Lower heater 13
Here you select if the lower immersion heater (13) should be included in
the operation.
The factory setting is “Yes”.
Def Elec. heater
Upper heater 14
Yes
Upper heater 15
No
Lower heater 13
Yes
!
“Upper immersion heater 15”
and the external boiler cannot
be used together.