39
For the property owner
CTC EcoZenith
I
550
Ext DHW tank °C
The temperature in the external hot water tank, if applicable. This tank can be used
to further increase the hot water capacity.
Ext DHW pump
The operation condition, “On” or “Off ”, for the circulating pump to the external
DHW tank.
DHWcirc. pump
The operation condition, “On” or “Off ”, for the circulating pump for DHWcirc.
Pool temp °C
Current pool temperature and the reference value towards which the
CTC EcoZenith
I
550 works.
Charge pump pool
The operation condition, “On” or “Off ”, for the charge pumps of the pool.
Mixing valve delay
The mixing valve is delayed the factory-set 180 min before it retrieves heat for the
radiator system from the upper part of the tank (additional heat). This line shows
the time remaining of the countdown to 0. The value can be set 0-240 min, and then
the mixing valve can be blocked so that it never takes heat from the upper part
of the tank. The setting is done in the “Installer/Settings/Elec. heaters” menu.
Electric power kW
Indicates how much power in kW by which the immersion heaters are driven
(upper immersion heater/lower immersion heater).
Current draw
Indicates the house’s total current draw on each of the phases. This presumes that
current sensors have been installed on the incoming lines. If the current exceeds
the set size of the main fuses, the electric boiler automatically disconnects power
in order to protect the fuses, for instance, when several power-demanding machines
are used in the house. The set main fuse size is indicated in brackets.
Prog. Date
The date of the control program version.