Operation / Technical Manual
NORM-O-TEMP, Model 111Z
Page 28 of 81
OPTION: The NORM-O-TEMP
®
unit can be mounted on an optional Low Profile
stand with casters or an optional I.V. Stand. For installation instructions, see
insert packaged with the stand.
B.
Visually inspect the NORM-O-TEMP
®
unit to determine that there are no missing
parts, dents, or punctures.
C.
Examine the power cord for cuts or exposed wires and the power plug for bent
or missing prongs.
D.
Review Section 1-3 to identify the features of the NORM-O-TEMP
®
unit.
E.
Collect and arrange the following equipment and supplies:
1.
Hyper-hypothermia blanket/pad(s) Listed in Figure 16.
2.
Connecting hose with quick-disconnect fittings (if applicable).
F.
Mount the NORM-O-TEMP
®
unit on the proper stand.
1.
To mount the NORM-O-TEMP
®
on IV Pole Stand:
i.
Place the NORM-O-TEMP
®
on the equipment pan with the rear of the
unit facing the IV pole. Slide the NORM-O-TEMP
®
toward the IV pole
until the rubber bumper touches the pole
ii.
Fasten the NORM-O-TEMP
®
by turning the knurled knobs (on the
underside of the equipment pan) clockwise into the threaded holes on
the bottom of the NORM-O-TEMP
®
. Hand tighten knurled knobs until
snug.
iii.
Fasten the mounting bracket around the lower IV pole near the
bumper on the rear of the Norm-O-Temp with the two stainless steel
machine screws provided.
2.
To mount the NORM-O-TEMP
®
on the Low Profile Stand:
i.
Place the NORM-O-TEMP
®
unit on the equipment pan so that the
threaded holes on the bottom of the unit line up with the knurled
knobs (on the underside of the equipment pan).
ii.
Fasten the NORM-O-TEMP
®
by turning the knurled knobs clockwise
into the threaded holes on the bottom of the Norm-O-Temp. Hand
tighten knurled knobs until snug.
G.
Slide the lid of the water fill opening and add 340 cc of propylene glycol then
gradually pour approximately 6 quarts (5.7 liters) of distilled water into the
reservoir. DO NOT USE DE-IONIZED WATER OR TAP WATER. Stop pouring
when the water reaches the strainer visible at the bottom of the water fill
opening. DO NOT OVERFILL.
Содержание NORM-O-TEP 111Z
Страница 14: ...Operation Technical Manual NORM O TEMP Model 111Z Page 14 of 81 Figure 1 NORM O TEMP unit Front View ...
Страница 16: ...Operation Technical Manual NORM O TEMP Model 111Z Page 16 of 81 Figure 2 NORM O TEMP unit Left Side View ...
Страница 18: ...Operation Technical Manual NORM O TEMP Model 111Z Page 18 of 81 Figure 3 NORM O TEMP unit Rear View ...
Страница 20: ...Operation Technical Manual NORM O TEMP Model 111Z Page 20 of 81 Figure 4 NORM O TEMP unit Right Side View ...
Страница 22: ...Operation Technical Manual NORM O TEMP Model 111Z Page 22 of 81 Figure 5 NORM O TEMP unit Model 111Z Top View ...