SERENITY – technician Guide
36
Address Description
Default
P32E
Pendant Buttons
-
Assign function to pendant's button. By
default button1 is assigned to Disarm, button2 - Arm, button 3
- Stay arm, button 4 - Switch output 1, button 5 - Panic.
(see
Description)
1.10: Users/Access Tag
Address
Description
Default
P33E
Learn access tag
-
An Access Tag/Card must be enrolled into
the panel before it can be used. The rights for tag or card for
each user is defined by options
[P36]
/ [P37] (Arm/Disarm) or
[P386] / [P387] (Turns output on/off).
Disable
Note: if access
tag is learned
by User mode
the options of
'Arm' and
'Disarm' are
automatically
enabled
P34E
Find access tag
-
If you have an Access Tag or Card loaded
into the panel but are unsure which location (User #), pressing
[P34]
while in Program Mode will start 'Find' Mode. Present the
Access Tag or Card you wish to find to a proximity reader
connected to the panel. If the Tag or Card is in memory the
keypad will display the number where the Tag or Card is stored.
Disable
P35E
Delete access tag
-
If you wish to delete a single Access Tag or
Card, entering
[P35]
and user number while in Program Mode
will delete the stored code against that user.
Disable
P36E
Access tag can arm
-
If this option is on, access tag can arm
all areas assigned at
[P14]
Disable
P37E
Access tag can disarm
-
If this option is on, access tag can
disarm all areas assigned at
[P14]
Disable
P386E
Access tag turns on output -
Any user's access tag can be
allowed to turn an Output ON. In this case Arm/Disarm
functionality for selected tag is not relevant. This Function can
be used to control external devices via access tags. Once an
Output is turned ON by a User, the Output can turn OFF again
automatically if a reset time is assigned to the Output, or it can
be turned off by the same user or by a different user with the
next program location
Disable
P387E
Access tag turns off output -
Any user's access tag can be
allowed to turn an Output OFF. In this case Arm/Disarm
functionality for selected tag is not relevant. This Function can
be used to control external devices via access tags. Once an
Output is turned OFF by a User, the Output can be turned on by
the same user or by a different user with the previous program
location
Disable
Содержание serenity
Страница 1: ...ELECTRONIC ENGINEERING LTD Serenity CONTROL PANEL Technician s Handbook Note this is a draft version...
Страница 29: ...29...
Страница 72: ......
Страница 73: ...73...