SERENITY – technician Guide
66
Address
Description – Maximum 4 digits per code /
Default
P306E
Area stay Arm Remote Control Code -
The control code value
has 1-4 digits. This code cannot starts from 0, Used when
accessing Serenity remotely.
Area 1stay = 51
:
Area 4stay= 54
P307E
Area disarm Remote Control Code -
The control code value has
1-4 digits. This code cannot starts from 0, Used when accessing
Serenity remotely.
Area 1disarm = 61
:
Area 4 disarm = 64
11:
Miscellaneous
11.0: Miscellaneous/Chime Control
Address Description
Default
P308E
Chime Alarm Beeps to Keypad –
If a zone is programmed as a Chime
zone and it activates, the zone can sound the buzzer at Selected
keypads for local alarm signaling. The duration of the Chime beep
is programmed at location P309E. The Chime function can also be
locally disabled at each keypad individually if not required.
Disable
P309E
Chime Alarm Beep Time
-
When a Chime Zone is activated it can
operate an Output and/or beep the keypad buzzer. There is a
separate Chime timer for each of the 8 keypads. If the value is
made '0' for a keypad the Chime Zone will not beep the keypad
buzzer. The Keypad Chime Timer can be set to a value from 1-
255. The units are in 1/10th second increments. This means that a
value of 10 will beep the keypad buzzer for 1 second
10
P1160E
Chime zone alarm assigned to output -
If a zone is
programmed as a Chime zone (P123E7E) and it activates, the zone
can trigger selected Outputs for local alarm signaling. The output
will operate for the Chime to Output time at location P41E. The
zone must clear before the output can be activated again
Disable
11.1: Miscellaneous/Panel Options
Address Description
Default
P310E
Installer Code
-
This code is used to enter full Installer
Programming mode. The default installer code is 000000. The
Installer Code must be between 4-8 digits in length if parameter is
enabled in (P327)
Disable
P311E
Duress Digit
-
The duress digit can be a number from 1-9 (a
value of '0' means the duress function is disabled). To create a
duress alarm the duress digit must be entered before a valid user
code (eg If the code was '123' and the duress number was '4',
then entering a code of '4123+ ENTER' would create a duress
alarm). Any user code or time-zone password cannot starts with
this digit for right duress recognition.
0
P312E
Disable mains fail test -
If the panel must be run off a DC
supply or the Mains supply fails regularly, this option disables the
mains voltage monitoring to prevent mains fail alarms from
occurring
Disable