3.6: Areas/Report Channel Assignment
Address
Description
Default
P1206E
Account Number
-
When reporting to a monitoring
Station there must be a unique account code programmed to
identify the area\s reported.
Each area has an account code. The account code is up to 4
characters for all protocols, except SIA and Voice message\SMS
(see notes below).
Each character can be a number from 0-9 as well as the special
characters B, C, D, E & F.
Take note that the number must be different than zero (0000
or 000000).
NOTE:
1. SIA protocol- 6 characters
2. All other protocols – 4 characters
3. You can use the characters 0-9 B,C,D,E,F
4. You don't need an ACC number When channel is
programmed as Voice message/SMS protocol
Disable
3.7: Areas/Signals to Outputs
Address
Description
Default
P77E
Arm Indication to Output
-
For monitoring purposes an Arm
indication can be assigned to an Output. This could be used to
start a video recorder or similar device. Each Area can have a
separate arm indication assigned to a different output if
required
Outputs 11-16
only
P78E
Stay Arm Indication to Output
-
For monitoring purposes a
Stay Arm indication can be assigned to an Output. Each Area
can have a separate indication assigned to a different output if
required
Outputs 11-16
only
P79E
Disarm Indication to Output
-
For monitoring purposes a
Disarm indication can be assigned to an Output. Each Area can
have a separate disarm indication assigned to a different output
if required
Outputs 11-16
only
P80E
Armed Exit Delay Beeps to Output
-
When an Area is Armed
it is useful to have the exit delay beeps occurring at the keypad
to warn the User to exit the premises without delay. If the
option is on at this address, that keypad will beep out the exit
delay. The exit beeps occur at one second intervals until the
last 5 seconds at which time they change to 1/2 second
intervals to act as a warning that the delay is about to expire
Disable
P81E
Stay Exit Delay Beeps to Output
-
When an Area is Armed in
Stay Mode it is useful to have the exit delay beeps occurring at
the keypad to warn the User to exit the premises without delay.
If the option is on at this address, that keypad will beep out the
exit delay. This option may be turned off for Stay Mode to make
the keypad silent when arming at night time. The exit beeps
occur at one second intervals until the last 5 seconds at which
time they change to 1/2 second intervals to act as a warning
that the delay is about to expire. When arming Stay Mode the
Disable