41
Address
Description
Default
enter Bypass mode the User must press BYPASS CODE ENTER
before they can bypass zones
P69E
Code required to Arm
-
If this option is turned on, the ARM
button is disabled and the panel requires a code to Arm
Disable
P70E
Arm command required before code to set
-
This option
determines if the ARM button must be pressed before a code is
entered to Arm an Area
Disable
P71E
Stay command required before code to set stay mode
-
This option determines if the STAY button must be pressed
before a code is entered to Arm Stay Mode
Disable
P72E
Report Arm on Exit Delay
-
If this option is on the panel will
report the Arm/Stay signal to a monitoring station when the
exit delay expires. If it is off, the panel will report the arm/stay
signal immediately after the system has been armed
Disable
P73E
Use near and verified alarm reporting for all zones
-
To
reduce the possibility of false alarms the panel can require two
alarms on different zones within a 45 minute period before a
full alarm will be sent. If this option is turned on it applies to all
zones assigned to that area. An alarm on a single zone will
send a Near Alarm report to the monitoring station. If no
further alarms occur within 45 minutes the near alarm timer is
reset and a restore is sent for the zone that activated. If the
zone that activated is still in alarm when the 45 minute timer
expires, a zone bypass for that zone will be sent and the zone
will remain bypassed until the area is disarmed. Any new
alarms after the timer has expired will send another Near Alarm
report. If a second alarm on a different zone occurs within 45
minutes of the Near alarm, an Intrusion Verified alarm report
will be sent.
This format applies to all protocols except SIA
PSTN, Voice message PSTN/GSM.
Disable
P393E
Unable to arm if exit zone is open -
If this option is turned
on, the system doesn't arm or stay arm the area if one of the
low security zones or exit delay zones is still open after the exit
delay expired.
3.1: Areas/Timers and Delays
Address Description
Default
P74E
Exit Delay Time
-
Each Area can have its own exit delay time.
The delay can be programmed from 1-255 seconds in one
second increments. If the exit delay is set to '0' the panel will
be instantly armed.
60
P75E
Stay Exit Delay Time
-
Each Stay Mode Area can have its own
exit delay time. The delay can be programmed from 1-255
seconds in one second increments. If the exit delay is set to '0'
the panel will be instantly armed.
60