61
Address Description
Default
P232E
Report Tests
-
If this option is turned on panel can send
automatic test connections, but if test connections are not
required they can be disabled by turning this option off.
Channels
3,4,5,7 – Off
All others - On
P234E
Report Stay Mode Zone Alarms
-
If this option is on, the panel
will report zone alarms in Stay Mode
Enable
P235E
Report output changed
-
The changing output state will be
reported via SMS or Voice reporting to the user
Channels
3,4,5,7 – Off
All others - On
P373E
Report Peripheral Tamper
-
If this option is on the panel will
report a Tamper Alarm from a peripheral module (extender
module or radio output) fitted with a tamper switch from a
peripheral module
Enable
P353E
Report Zone Confirmed Alarm -
If this option is on the panel
will report a Zone Confirmed (Near and Verified) Alarms (see
[P73]
)
Channels
3,4,5,7 – Off
All others - On
10:
Communications
10.0: Communications/Remote Access
Address Description
Default
P236E
Remote Access Password
–
up to 8 character password for
remote pc application access.
Disable
P237E
Remote Access only if disarmed
-
if this option is on the
Remote access option is allowed only in disarmed state.
Disable
P388E
Enable Direct Remote Access -
This option uses for remote
user remote control of the system via string commands. Due to
the fact that this option works on an open non-secure protocol
its use is recommended only for testing or to use the control
panel as part of another system (such as Home Automation
system).
Disable
P233E
Remote Access Server -
This parameter defines IP-address or
DNS name of remote access server. The server using for remote
access (WEB access for example), and control panel should to
make registration on server to provide remote access.
Disable
P246E
Remote Access Server Port -
This parameter defines port on
remote access server the control panel using fore registration
procedure.
Disable
P316E
Server Registration Time -
The time of periodical confirmation
of registration on remote access server. Using for check
validation of control panel address on server. If control panel use
constant IP, the parameter can be set to 0.
15m
P317E
Remote Access From Server Only -
If this flag is ON remote
access can be accepted from Remote Access Server after
successful registration only.
Disable
10.1: Communications/Phone Line communication Options
Address Description
Default