Address Description
Default
channels, but if the active channels fail simultaneously,
the backup will send a report only from the first channel
to fail
Step 6: Areas Account Number
Address Description
Default
P206E
Account Number
- -
When reporting to a monitoring
Station there must be a unique account code programmed to
identify the area\s reported.
Each area has an account code. The account code is up to 4
characters for all protocols, except SIA and Voice message\SMS
(see notes below).
Each character can be a number from 0-9 as well as the special
characters B, C, D, E & F.
Take note that the number must be different than zero (0000 or
000000).
NOTE:
1. SIA protocol- 6 characters
2. All other protocols – 4 characters
3. You can use the characters 0-9 B,C,D,E,F
4. You don't need an ACC number When channel is
programmed as Voice message/SMS protocol
All Zeros
A letter - not
in use
Step 7: Area Names
Address
Description
Default
P93E
Area Name
-
Enter the Area name
,
up to 16 characters
" Area #"
Step 8: Area Exit Delay Time
Address Description
Default
P74E
Exit Delay Time
(sec) -
Each Area can have its own exit delay
time. The delay can be programmed from 1-255 seconds in one
second increments. If the exit delay is set to '0' the panel will
be instantly armed.
60
Step 9: Learn Radio Zone
Address Description
Default
P177E
Learn Radio Zone
-
Radio detector must be enrolled into the
panel before it can be used. pressing of Detector's tamper
switch will be used for learning operation
Disable
Step 10: Exit Delay Zone