Installation & Reference Guide — DOC. 5822
Abort
Voting Console
Description
Abort voting sequence
Direction
Voting Computer to control system
Type
Digital
Value
Assert:
Results now being recorded on Voting Computer
([
Print &
]
Save Results
button feedback ON)
De-assert:
Results have been recorded
([
Print &
]
Save Results
button feedback OFF)
Expected Reply
AgendaEcho, NewVote,
Comments
This signal is accepted by the Voting Computer while the floor is opened and after
the floor is closed but before the vote is recorded. When accepted, voting computer
responds as follows (in the order given):
§
All “state” signals are de-asserted
§
NewVote
pulse
§
All digital “tally” signals are de-asserted and analog “tally” signals are reset to 0
§
All
Change
s
signals are reset to 1 (present) if aborting attendance taking or either 0
(absent) or 1 (present) if aborting a vote
§
AgendaEcho
with the value “[Vote aborted]”
Used in conjunction with the other “state” signals,
StateStart, StateEnd,
and
StateDisplay
; and the pulsed signals,
NewVote
and
AgendaTrigger
. These
signals provide feedback to the control system about the voting sequence. They
can be used to highlight the sequence control buttons, or to enable/disable
touchpanel choices. (See “State Coordination,” page 61, for a “score sheet”
illustrating the sequence.)
This signal is only valid during a vote (when
StateStart, StateEnd,
or
StateDisplay
is high). If issued at the wrong time, the following descriptive error
message is sent through the
ErrString
signal:
To start, press TAKE ATTENDANCE or START VOTE
See Also
PrintSave, AgendaEcho, NewVote